MA-K17510-KW LinerSCAN manual ISSUE P.doc
Page 38 of 93
4.4 Fault Finding
4.4.1 Blockages
The LinerSCAN sensors rely on the air-blast cleaning technique to keep pipe work clear. After pre-
installation, the valves are closed and left until commissioning. During this time blockages can occur,
leading to no oil getting to the sensors. The system does have a blockage alarm; however this is
usually seen once the engine has been operated.
If a short voyage is not possible to check adequate filling of the sensors – for example in port
commissioning only; perform a ‘blockage test’ for each sensor during commissioning, as detailed in
the ‘Troubleshooting and Fault Finding’ section.
4.4.2 General Fault Finding
Refer to the fault finding and troubleshooting section at the back of this manual.
Содержание FG-K17401-KW
Страница 9: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 8 of 93 3 Installation Installation ...
Страница 34: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 33 of 93 4 Commissioning Commissioning ...
Страница 40: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 39 of 93 5 Operation Operation Manual ...
Страница 57: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 56 of 93 6 Interpreting Results Interpreting Results ...
Страница 89: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 88 of 93 ...