7.4 Oil Flow Testing
This test is used to verify that oil flows into the sensor.
The vessel should be on an even keel, otherwise oil may flow away from the scavenge space exit
pipe.
1. Turn power to the sensor off
2. Turn air supply to the sensors off
3. In port (engine off) open the scavenge inspection cover – to gain access to the bottom of the
cylinder liner.
4. Open the isolation valves for oil IN to the sensor. The scavenge drain valve must also be
OPEN.