Digi Cell Plus - Digital Oil Test Cell Information Guide
8
GB
Technical Specification
*EasySHIP reagent must be >18 °C before use.
**Extremes of temperature will reduce battery life.
Power (from USB)
Micro-USB: 5 V 100 mA minimum
Tests Per Charge
50 tests or 5 hours
Minimum Battery Charge Cycles
500
Maximum Storage Time From Full Battery
6 months (stored between -5 °C to 35 °C)
Operating Temperature *
10 °C to 45 °C
Storage Temperature **
-20 °C to 60 °C
Material Compatibility
Mineral and synthetic fluids compatible with FKM (Viton(tm)) elastomer seals. Lubricant oils, hydraulic oils,
distillate fuels, and Bio-based fuels.
Unit Dimensions
112 mm maximum height x 76 mm diameter
Mass
200 g
Water
BN
Measurement Range (v/v)
Measurement Range (mg KOH/g)
0.1 % to 20.0 %
0.1 % to 10.0 %
0.02 % to 1.00 %
200 ppm to 10000 ppm
100 ppm to 3000 ppm
1 to 150
Water Range Resolution
BN Resolution
0.1 % to 20.0 %
0.1 % to 10.0 %
0.02 % to 1.00 %
200 ppm to 10000 ppm
100 ppm to 3000 ppm
0.1 %
0.1 %
0.1 %
50 ppm
10 ppm
1 BN
Water Accuracy
BN Accuracy
100 ppm to 10000 ppm
> 1 %
Typically ± 1000 ppm
Typically ± 1 %
± 5 BN or 10 % (whichever is greater)
Test Time
Test Time
180 seconds
120 seconds