Digi Cell Plus - Digital Oil Test Cell Information Guide
23
GB
SPID
(Smart
features)
– Overview and setup
Smart features are automatically launched when DIGI+ is connected to a PC (Windows and Mac), providing the ability
to record results and to export for further analysis. The SPID structure provides a guided approach to measurements,
ensuring all samples are measured in order. The smart capability of DIGI+ provides reassurance for the user by optimising
data integrity and minimising missing test points, making it easier to spot out-of-range results. After taking measurements
following the list of SPIDs, results are saved to DIGI+ internal drive (DIGI Drive). DIGI+ can then be connected to a PC
and the SPID measurement data exported from DIGI Drive to the PC.
For time-efficiency, the oil reference list for BN measurement may be configured via the PC rather than entered manually
via the DIGI+ keypad.
The user connects DIGI+ to a PC to:
DIGI+:
• can be configured manually with no special software
• works with any computer that supports MS-DOS (FAT12) – including MS Windows and Macintosh
• does not behave like a USB mass storage device but rather dynamically creates the csv files when connected to a PC
• file format is ‘Comma-Separated Values’.csv
It is only possible to drag and drop the DIGI_CFG file. Other files copied to the DIGI Drive are deleted. If files are deleted
from the DIGI Drive, they are automatically recreated at next connection to a PC.
1 Create, edit and import an OIL TYPE list / Sample Point Identification (SPID) list
PC
u
DIGI+
2 Export SPID measurement data
DIGI+
u
PC