Parker DIGI+ Скачать руководство пользователя страница 38

GB

© 2021 Parker Hannifin Corporation. All rights reserved.

European Product Information Centre
Free phone: 00 800 27 27 5374
(from AT, BE, CH, CZ, DE, DK, EE, ES, FI, 
FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, 
SE, SK, UK, ZA)

Europe, Middle East, 

Africa

AE – United Arab Emirates, 

Dubai 
Tel:  +971 4 8127100

AT – Austria, 

St. Florian 

Tel:  +43 (0)7224 66201 

AZ – Azerbaijan, 

Baku 

Tel: +994 50 2233 458

BE/NL/LU – Benelux,  

Hendrik Ido Ambacht 
Tel: +31 (0)541 585 000

BY – Belarus, 

Minsk 

Tel: +48 (0)22 573 24 00

CH – Switzerland, 

Etoy 

Tel: +41 (0)21 821 87 00 

CZ – Czech Republic,  

Prague 
Tel: +420 284 083 111

DE – Germany, 

Kaarst 

Tel: +49 (0)2131 4016 0

DK – Denmark, 

Ballerup 

Tel: +45 43 56 04 00

ES – Spain, 

Madrid 

Tel: +34 902 330 001

FI – Finland, 

Vantaa 

Tel: +358 (0)20 753 2500

FR – France, 

Contamine s/Arve 

Tel: +33 (0)4 50 25 80 25

GR – Greece

 

Tel: +30 69 44 52 78 25

HU – Hungary, 

Budaörs 

Tel: +36 23 885 470

IE – Ireland, 

Dublin 

Tel: +353 (0)1 466 6370

IL – Israel

 

Tel: +39 02 45 19 21

IT – Italy, 

Corsico (MI) 

Tel: +39 02 45 19 21

KZ – Kazakhstan,

 Almaty 

Tel: +7 7273 561 000

NO – Norway, 

Asker 

Tel: +47 66 75 34 00

PL – Poland, 

Warsaw 

Tel: +48 (0)22 573 24 00

PT – Portugal

 

Tel: +351 22 999 7360

RO – Romania, 

Bucharest 

Tel: +40 21 252 1382

RU – Russia, 

Moscow 

Tel: +7 495 645-2156

SE – Sweden, 

Borås 

Tel: +46 (0)8 59 79 50 00

SL – Slovenia, 

Novo Mesto 

Tel: +386 7 337 6650

TR – Turkey, 

Istanbul 

Tel: +90 216 4997081

UK – United Kingdom, 

Warwick 

Tel: +44 (0)1926 317 878

ZA – South Africa, 

Kempton Park 

Tel: +27 (0)11 961 0700

North America

CA – Canada, 

Milton, Ontario 

Tel: +1 905 693 3000

US – USA, 

Cleveland  

Tel: +1 216 896 3000

Asia Pacific

AU – Australia, 

Castle Hill 

Tel: +61 (0)2-9634 7777

CN – China, 

Shanghai 

Tel: +86 21 2899 5000

HK – Hong Kong 

Tel: +852 2428 8008

IN – India, 

Mumbai 

Tel: +91 22 6513 7081-85

JP – Japan, 

Tokyo 

Tel: +81 (0)3 6408 3901

KR – South Korea, 

Seoul 

Tel: +82 2 559 0400

MY – Malaysia, 

Shah Alam 

Tel: +60 3 7849 0800

NZ – New Zealand, 

Mt Wellington 

Tel: +64 9 574 1744

SG – Singapore 

Tel: +65 6887 6300

TH – Thailand, 

Bangkok 

Tel: +662 186 7000

TW – Taiwan, 

Taipei 

Tel: +886 2 2298 8987

 

Parker Worldwide

South America

AR – Argentina, 

Buenos Aires 

Tel:  +54 3327 44 4129

BR – Brazil, 

Sao Jose dos Campos 

Tel:  +55 080 0727 5374

CL – Chile, 

Santiago

 

Tel: +56 22 303 9640

MX – Mexico, 

Toluca 

Tel: +52 72 2275 4200

Digi Cell Plus - Digital Oil Test Cell Information Guide

38

Содержание DIGI+

Страница 1: ...DIGI Digi Cell Plus Digital Oil Test Cell MA K32184 Rev 1 0 2021 Parker Hannifin Manufacturing Ltd www parker com...

Страница 2: ...OIL TYPE List Name BN Value Calibration 16 Cleaning 17 Testing 18 Test Menu Navigation 18 Water H2 O Single Test 18 Base Number BN Single Test 19 Measure Used Oil 19 Interpreting Results 20 Water 20...

Страница 3: ...l Test Cell Information Guide 3 GB Contents Maintenance Servicing 34 Shipping Note 34 Troubleshooting 35 Measurement 35 BN specific Measurement 35 Results 36 Result Comparison 37 Connectivity Battery...

Страница 4: ...y DIGI Base Number BN only DIGI Combined H2 O and BN Smart Setup Data Storage Rechargeable Battery DIGI provides a refreshed but familiar interface with the addition of smart features to enhance the u...

Страница 5: ...f safety glasses and or protective gloves General this information guide should be read in full before operating DIGI appropriate safety measures must be taken when handling both combustible and flamm...

Страница 6: ...Adequate ventilation must be ensured to avoid H2 build up in a confined space H2 gas is explosive at concentration levels above 4 Conformity This equipment is CE marked approved for the EEA market an...

Страница 7: ...from a chemical that reacts with available water in the sample The water content is calculated from the gas pressure in the sample cup Base Number of Oil Measurement Gas is generated from a chemical...

Страница 8: ...Mineral and synthetic fluids compatible with FKM Viton tm elastomer seals Lubricant oils hydraulic oils distillate fuels and Bio based fuels Unit Dimensions 112 mm maximum height x 76 mm diameter Mass...

Страница 9: ...icing Accessories PPE reagents syringes and consumables DIGI Agitator DIGI Water H2 O and DIGI Combined variants Micro USB charging cable Quick Test Guide printed copy Contact consumables and spares i...

Страница 10: ...Digi Cell Plus Digital Oil Test Cell Information Guide 10 GB Manufacturer Information Consumables Spares For service please see the Contact consumables and spares information sheet...

Страница 11: ...lly with micro USB cable before first use DIGI requires a fully charged battery prior to initial use to accurately measure the remaining life Refit USB socket cover Fully charged battery run time 50 t...

Страница 12: ...Left L Middle M or Right R button to power on Backlight turns off after 20 seconds Press any button to re activate Opening Closing Hold the sample cup and turn the upper counter clockwise Hold the sam...

Страница 13: ...o sample the entire group of units components to establish initial baseline data and quickly spot any components with serious problems Once this process is complete then it is possible to set an initi...

Страница 14: ...is generated from a chemical that reacts with available remaining BN additive in the sample Gas pressure from used oil is compared to new oil as a ratio Pressure is generated in DIGI proportional to t...

Страница 15: ...dited by entering the oils list in set up The OIL TYPE is structured in DIGI into separate lists as below 1 2 3 4 5 6 7 8 SUPERLUBE HS CYLGARD LS CYLGARD SYS LUBE_Y ENGINEOILW ENGINEOILA EP GEAR ULTRA...

Страница 16: ...cess Action Visual Description To assign a name to OILs OILs OK q to select OIL TYPE OK NAME uq to select character NEXT Repeat steps above and when finished press NEXT repeatedly until OIL TYPE NAME...

Страница 17: ...ly 2 DIGI body upper and sample cup including agitator for H2 O testing should be thoroughly cleaned Attention should be paid to ensuring no reagent residue is left in the O ring and threaded surfaces...

Страница 18: ...e paid to the seal See Cleaning EasySHIP reagent must be above 18 C and should be shaken thoroughly Test Menu Navigation Water H2 O Single Test RANGE OK START Select the test range for the approximate...

Страница 19: ...the OIL TYPE is already calibrated DIGI automatically selects measurement screen calibration takes place automatically if an uncalibrated OIL TYPE is selected see BN Calibration for further detail Bas...

Страница 20: ...kdown of oil film conditions Alternatively the mode of failure could be progressive resulting from local or generalised corrosion of components within the systems and or through effects which impact o...

Страница 21: ...ial sump volume The governing factor for the stable final BN level is the oil consumption rate and the fuel sulphur level Rapid BN decrease is caused by low oil consumption small sump volumes high fue...

Страница 22: ...quency in days Enclosed Gear Oils 0 15 0 2 0 2 Check upper limit against OEM data 30 Compressor Oil 0 1 0 1 Water can enter via compressor cylinders always check inter cooler drains are operating effe...

Страница 23: ...PC and the SPID measurement data exported from DIGI Drive to the PC For time efficiency the oil reference list for BN measurement may be configured via the PC rather than entered manually via the DIG...

Страница 24: ...ome Screen Select Test Type BN q to Add Oil CAL q to see OIL TYPES Imported OIL TYPES appear in SETUP OILS list below first 8 OIL TYPES Note OIL TYPE is not editable via DIGI keypad but is editable vi...

Страница 25: ...the drive list as DIGI DRIVE X Make changes to OIL TYPE list Save file or replace one on DIGI DRIVE X Importing edited OIL TYPE List to DIGI Connect DIGI to a PC Connect to PC using micro USB cable D...

Страница 26: ...ing a reassuring real time result indication Result within pre set alert limits Result above pre set alert limits Result outside of range NOT EDITABLE 1 2 3 4 5 6 7 8 SUPERLUBE HS CYLGARD LS CYLGARD S...

Страница 27: ...be on the drive list as DIGI DRIVE X Complete SPID list Save file or replace one on DIGI DRIVE X Creating a Sample Point Identification SPID List via a PC and Importing to DIGI Importing SPID List to...

Страница 28: ...will be on the drive list as DIGI DRIVE X Make changes to SPID list Save file or replace one on DIGI DRIVE X Importing edited SPID List to DIGI Connect DIGI to a PC Connect to PC using micro USB cabl...

Страница 29: ...hen archived and is available to be imported into a PC as a results csv file If a result is below the range used the value stored is the minimum detectable limit for the range either 0 1 0 02 200 ppm...

Страница 30: ...lumns are being edited See online guidance on using csv files 0 X SPIDs Done Select SPID to measure DIGI DRIVE connected to PC SPID Data Archive saved SPID Data SET CLOSED and archived New SET automat...

Страница 31: ...aximum of 3 SPID sets can be archived DIGI has a SPID set memory that is first in first out FIFO IMPORTANT to stop data loss copy files from DIGI to a PC before starting a 4th SPID SET until the SPID...

Страница 32: ...uide 32 GB Visual Description SPIDs OK Delete OK YES YES Visual Description Reset OK YES YES Back to SETUP Back to SETUP Clearing DIGI Memory To delete SPID data and disable smart functionality DIGI R...

Страница 33: ...al Oil Test Cell Information Guide 33 GB DIGI Utility A utility to configure DIGI download data and view trends in the SPIDs is available See the Contact consumables and spares information sheet for l...

Страница 34: ...as been designed with precision components for long term measurement accuracy therefore no periodic recalibration is necessary Where quality systems require or risk assessments indicate that accuracy...

Страница 35: ...ghtening by hand 1 8 turn only after the sample cup makes contact with the seal Tools should not be used to tighten DIGI Screen does not a respond to button press or b sleep after 5 minutes Reset requ...

Страница 36: ...cause damage Results lower than expected Not enough reagent added Ensure EasySHIP reagent is above 18 C and entire tube is emptied into the sample cup Sample oil and or reagent volume incorrect All te...

Страница 37: ...or IR methods such as FTIR or NDIR can give different measurements and have their own non repeat and accuracy issues Laboratory methods also measure the total amount of water present DIGI reagent reac...

Страница 38: ...r Tel 47 66 75 34 00 PL Poland Warsaw Tel 48 0 22 573 24 00 PT Portugal Tel 351 22 999 7360 RO Romania Bucharest Tel 40 21 252 1382 RU Russia Moscow Tel 7 495 645 2156 SE Sweden Bor s Tel 46 0 8 59 79...

Отзывы: