
Parker EME
Setting up Compax3
192-120100 N16 C3I10T10 - December 2010
137
2011.1: Filter external rotation speed feedforward
Unit: %
Range: 0 ... 550
Standard value: 500*
* Depending on the operating mode
With ±10V analog setpoint control the standard value = 0; otherwise 500.
2010.2: Acceleration feed-forward
Unit: %
Range: 0 ... 500
Standard value: 100%
t
t
2
1
3
4
Additional effect of forward acceleration control
1: Speed setpoint value
2: Actual speed value
3: Motor current
4: Following error
2011.2: Filter external acceleration feedforward
Unit: %
Range: 0 ... 550
Standard value: 500%
2010.4: Current feed-forward
Unit: %
Range: 0 ... 500
Standard value: 0%