Setting
up Compax3
C3I10T10
104
192-120100 N16 C3I10T10 - December 2010
Simulated Encoder Output Resolution
Unit: Incremen
ts per
revolution / pitch
Range: 4 - 16384
Standard value: 1024
Any resolution can be set
Limit frequency: 620kHz
(track A or B)
i.e. , with:
Increments per revolution
max. Velocity
1024
36000 rpm
4096
9000 rpm
16384
2250 rpm
Invert Motor Rotation/Direction Polarity
Unit:
-
Range: no / yes
Standard value: no
Reverse direction inverts the sense of rotation, i.e. the direction of movement of the motor
is reversed in the case of equal setpoint.
Time frame predefined setpoint value
Averaging and a following filter (interpolation) can help to avoid steps caused by
discrete signals.
If the external signal is analog, there is no need to enter a value here (Value = 0).
For discrete signals e.g. from a PLC, the scanning time (or cycle time) of the signal
source is entered.
T
t
This function is only available if the analog int/-10V is used!
4.1.7.2
Step/Direction Input 24V
Required wiring:
Plug/Pin
Assignment
X12/13
Step
X12/14
Direction
X12/15
0V
4.1.7.3
Step/Direction Input RS422
Input:
RS422