Setting
up Compax3
C3I10T10
128
192-120100 N16 C3I10T10 - December 2010
4.4.3.4
Tips
Tip Problem
Measures
1
Speed too low
(with reverse operation)
Increase maximum speed and adapt travel
range*
2
Speed too low
(with continuous operation)
Increase maximum speed
3
Test movement missing
A test movement is important for drives with
high friction or with mechanical slack points
(play).
4
No error detected
Please note the
boundary conditions
(see
on page 126).
5
Speed too low and amplitude of
the excitation signal too small
(with reverse operation)
Increase amplitude of the excitation signal;
increase maximum speed and adapt travel
range*
6
Speed too low and
amplitude of the excitation
signal too small
(with continuous operation)
Increase amplitude of the excitation signal;
increase maximum speed.
7
Test movement missing
amplitude of the excitation
signal too small
Increase amplitude of the excitation signal
or / and
activate an appropriate test movement
8
amplitude of the excitation
signal too small
Increase the amplitude of the excitation
signal.
9
Following error occurred
Increase the parameter "permissible
following error" or decrease the amplitude of
the excitation signal.
*if the travel range is too short, the speed is not increased, as the drive does not