Parker EME
Setting up Compax3
192-120100 N16 C3I10T10 - December 2010
115
The device can be brought into various states via the inputs:
I0: Energize motor,
I1: Enable Setpoint value
and
I2: Ackn
I3: Open brake
the device is brought into various device states.
The transitions are implemented via
ramps
(see on page 107) and the controlled
switching of
motor brake
(see on page 143).
The ramps are not used in the "±10V analog current setpoint” operating
mode!
An error can occur in any device state. For reactions to the different error causes
please see the
Error list
(see on page 164).