Bulletin TI-FID1000C 

FID 1000 and 2500 Gas Stations

Parker Hannifin Corporation

Filtration and Separation Division

Haverhill, MA • 1-800-343-4048 

www.parker.com/ags

20

System Specifications, Parts, Accesssories

System Specifications

  

 

 

FID 1000 

 

FID 2500

Hydrogen Purity 

99.9995% 

 

99.9995%

ZAG Purity 

<0.1 ppm Methane in Air Challenge 

<0.1 ppm Methane in Air Challenge

CSA Certification Standard  

CAN/CSA C22.2 No 1010.1-92 

CAN/CSA C22.2 No 1010.1-92

IEC Certification Standard 

IEC 1010/EN61010-1 

 

IEC 1010/EN61010-1

IEC 1010 Installation Category 

Category 11 

 

Category 11

IEC 1010 Pollution Degree 

Degree 2 

 

Degree 2

UL Safety Standard 

UL 3101-1, First Edition 

 

UL 3101-1, First Edition

EMC Compliance 

CISPR11:EN55011:1991/EN50082-1:1992 

CISPR11:EN55011:1991/EN50082-1:1992

Maximum Flow rate 

 

1000cc/min (ZAG) 

 

2500 cc/min (ZAG)

 

90cc/min (H2)  

 

250 cc/min (H2)

Total Hydrocarbon Concentration 

0.1 ppm 

 

0.05 ppm

Max Inlet Hydrocarbon Concentration 

100 ppm 

 

100 ppm

 

Pressure Drop at Max. Flow rate 

< 5 psid (0.3 bar ) 

 

< 5 psid (0.3 bar )

Outlet Air Temperature 

a 20°F (+ 11°C) 

 

a 20°F (+ 11°C) 

Discharge Pressure

 

0-90 psig ( 0-6.2 barg ) 

 

0-90 psig ( 0-6.2 barg )

Hydrogen Outlet Port 

1/8" compression, SS 

 

1/8" compression, SS

ZAG Outlet Port 

1/8" compression, Brass 

 

1/8" compression, Brass

 

Hydrogen Relief Port 

1/4" Female NPT 

 

1/4" Female NPT

Compressed Air Inlet Port

 

1/4" Female NPT 

 

1/4" Female NPT

Water Requirements 

Deionized Water (> 5 Meg-Ohm /cm) 

Deionized Water (> 5 Meg-Ohm /cm)

Max. Ambient Relative Humidity 

80 %

  

 

80 %

 

Min/Max Ambient Temperature 

60°F/100°F (16°C/40°C) 

 

60°F/100°F (16°C/40°C)

Min/Max Inlet Pressure 

40/125 psig (2.7 barg/8.5 barg )

 

 

40/125 psig (2.7 barg/8.5 barg )

Altitude 

2000 M 

 

2000 M

Electrical Requirements  

100-120/200-240 VAC,47-63Hz

   

100-120/200-240 VAC,47-63Hz

  

Power Consumption 

480 Watts @ 110 vac, 460 watts @ 220 vac 

480 Watts @ 110 vac, 460 watts @ 220 vac

Start Up Time 

45 minutes 

 

45 minutes

Fuses                            120 vac: 

5 x 22 mm, Type T, 250 V, 3.15 Amp 

5 x 22 mm, Type T, 250 V, 3.15 Amp

 

                                      220 vac: 

5 x 22 mm, Type T, 250 V, 2.0 Amp 

5 x 22 mm, Type T, 250 V, 2.0 Amp

Product Dimensions 

13"w x 20"h x 23"d (33cm x 51cm x 58cm) 

13"w x 20"h x 23"d (33cm x 51cm x 58cm)

Product Weight/Shipping Weight 

53 lbs (24 kg) 

 

53 lbs (24 kg)

Replacement Parts

Description 

FID 1000 

FID 2500 

 Frequency

Resin Bed Cartridge 

B02-0323 

B02-0323 

When Color Changes 3/4

Dessicant Cartridge 

1647727 

1647727 

When Color Changes

Fuses (117 vac, 3.15 Amp) 

13216 

13216 

As needed

Fuses (220 vac, 2 Amp ) 

13192 

13192 

As needed 

Maintenance Kit 

MK7583 

MK7583 

1 Year

ZAG Catalyst Module 

B02-0298 

B02-0361 

2 Years

H2 Cell Assembly 

B02-0313 

7601619 

As needed

DIO Water Fill Solenoid 

B02-0315 

B02-0315 

As needed

Auto-drain Solenoid 

75612 

75612 

As needed

Recommended Accessories

Accessory 

P/N

Pressure Regulator (0-130 psig ) 

72-130-V883

Installation Kit 

IK76803

Condenser Assembly 

72-100

Flowmeter 

W-FM7583

HydroGen™ Mate 

72-231

 

* To ensure consistent product 

performance and reliability use 

only genuine Balston replacement 

parts and filter cartridges.

Parker Hannifin UK Ltd

Filter Division Europe

Hermitage Court, Hermitage Lane

Maidstone, Kent ME16 9NT, England

Tel:  +44 (0) 1622-723300  Fax:  +44 (0) 1622-728703

©Parker Hannifin Corporation   2003, 2006

Printed in U.S.A.   Bulletin TI-FID1000C

Parker Hannifin Corporation

Filtration and Separation Division

242 Neck Road, P.O. Box 8223

Haverhill, MA 01835-0723

Tel:  978-858-0505  Fax:  978-858-0625

Содержание Balston FID 1000

Страница 1: ...source of hydrocarbon free air This will purify on site compressed air to a total hydrocarbon concentration of less than 0 1 ppm measured as methane The ZAG may be used to generate fuel for Flame Ioni...

Страница 2: ...and particulate contamination from the incoming compressed air supply The pre lter assembly is equipped with an solenoid autodrain to eliminate any liquids which have accumulated within the lter hous...

Страница 3: ...urs inside the electrochemical cell assembly Figure 3 Positively charged hydrogen ions are transported across the solid polymer electrolyte along with excess water molecules The hydrogen ions then rec...

Страница 4: ...ould be located in close proximity to the electrical power supply and the downstream equipment to which it supplies both Hydrogen and Zero grade air There is no limit to the distance between the gener...

Страница 5: ...cal power supply voltage Note NA versions of the generator are designed for 120 VAC operation only Deionized Water The FID 1000 and FID 2500 hydrogen must be supplied with deionized water with a resis...

Страница 6: ...d is located at the top center of the rear panel Inlet tubing and ttings should be clean and rated for 125 psig 8 5 Barg minimally The tubing and ttings used downstream from the FID 1000 and FID 2500...

Страница 7: ...iltration and Separation Division Haverhill MA 1 800 343 4048 www parker com ags 7 Figure 6 Unscrew desiccant cap Figure 7 Insert new desiccant cartridge Figure 8 Press down rmly on desiccant to seat...

Страница 8: ...ly The FID Gas Station H2 must be supplied with deionized water with a resistivity of at least 5 Meg Ohm cm or greater Both a Gravity Feed and a Pressure Feed Tubing assembly can be located in the Acc...

Страница 9: ...he device until the desired water level is visible through the Front Panel Display Replace the cap and close the side cover lid It will take approximately 2 liters of deionized water to ll the generat...

Страница 10: ...er in the reservoir above the REFILL line at all times or ensure that the FID Auto ll is directly connected to a DIO water source 2 Minimize the dead volume in the piping between the generator and the...

Страница 11: ...carbons HYDROGEN Over ow in Use 0 0 0 psi ZERO AIR At temperature HYDROGEN in Use 79 66 5 psi ZERO AIR At temperature HYDROGEN add water in Use 79 66 5 psi ZERO AIR At temperature PARKER HANNIFIN ZERO...

Страница 12: ...ipment 3 Fill the DIO Reservoir at least half full with deionized water Make sure that the cell has at least 2 5cm of water showing in the cell assembly tube This can be viewed through the vents in th...

Страница 13: ...external system piping for leaks Shutdown then restart generator Check internal system piping for leaks Shutdown then restart generator No Hydrogen Delivered Check power connections see above Check w...

Страница 14: ...lletin TI FID1000C FID 1000 and 2500 Gas Stations Parker Hanni n Corporation Filtration and Separation Division Haverhill MA 1 800 343 4048 www parker com ags 14 Figure 12 FID Gas Station Exploded Vie...

Страница 15: ...rade BXE pre lter will be accessible from the side of the generator after the generator cover is removed The lter cartridge inside the housing should be changed on an annual basis to maintain ef cient...

Страница 16: ...astic parts in the genera tor These uids may cause cracking and crazing which leads to part failure Use a solution of 4 5 ml of liquid dish soap in one liter of water Re ll the water in the generator...

Страница 17: ...ration Filtration and Separation Division Haverhill MA 1 800 343 4048 www parker com ags 17 Figure 14 View Toward Rear of Unit Model FID 2500 Figure 15 Thermocouple wire Figure 16 Rear View FID 2500 s...

Страница 18: ...one hour to remove any residual oxygen and moisture from the instrument and piping downstream When the desiccant becomes saturated with moisture the blue indicating color will turn beige or gray or t...

Страница 19: ...he fuses in the FID gas station may burn out The fuses are located in the power receptacle on the back side of the generator Before servicing the fuse turn the unit off and disconnect the power cord f...

Страница 20: ...e 40 125 psig 2 7 barg 8 5 barg 40 125 psig 2 7 barg 8 5 barg Altitude 2000 M 2000 M Electrical Requirements 100 120 200 240 VAC 47 63Hz 100 120 200 240 VAC 47 63Hz Power Consumption 480 Watts 110 vac...

Страница 21: ...ay be hot and could cause burns to the skin found on inside of some units Under certain conditions metal cabinet will be warm to touch 70 C 3 Explanation of Warning Symbols Parker Hanni n UK Ltd Filte...

Отзывы: