Application ‘1’: Standard (Basic Speed Control)
This Application is ideal for general purpose applications. It provides push-button or switched start/stop
control. The setpoint is the sum of the two analogue inputs AIN1 and AIN2, providing Speed Se
Speed Trim capability.
Configuration Setup:
RL1A
110-230 VAC (or 24 VDC) voltage supply
RL1B
Healthy:
Relay output (to lamp)
TH1
Motor Thermistor ‘+’ connection
TH2
Motor Thermistor ‘-’ connection
AI1
Remote Setpoint (%)
– input 1:
0-10 V variable input (from potentiometer)
AI2
Remote Setpoint ‘Trim’ (%) – input 2:
4-20 mA variable input (from current source)
AO1
Speed Demand (%):
0-10 V variable output (to voltmeter)
AO2
Value = 100%:
0-10 V variable output (+10V fixed reference voltage)
DX1
Run Forward:
24 V digital input
DX2
Remote Reverse:
24 V digital input
DX3
Jog:
24 V digital input
DI4
Not Stop:
24 V digital input
DI5
Not Coast Stop:
24 V digital input
STO
STO
DISABLED
(drive operational)
V
↑
V
S
Содержание AC20F Series
Страница 144: ...MSG11 5715 743 EN AC20F Series Hardware Installation Manual 144 148 MSG11 5715 743 EN 24 04 2023 Frame 3...
Страница 145: ...MSG11 5715 743 EN AC20F Series Hardware Installation Manual MSG11 5715 743 EN 24 04 2023 145 148 Frame 4 Frame 5...
Страница 146: ...MSG11 5715 743 EN AC20F Series Hardware Installation Manual 146 148 MSG11 5715 743 EN 24 04 2023 Frame 6 Frames 7 8...
Страница 147: ...MSG11 5715 743 EN AC20F Series Hardware Installation Manual MSG11 5715 743 EN 24 04 2023 147 148 Frame 9 Frame 10...
Страница 148: ...MSG11 5715 743 EN AC20F Series Hardware Installation Manual 148 148 MSG11 5715 743 EN 24 04 2023...