18
6K Hardware Installation Guide
CONNECTIONS TO THE LINEARSERV DRIVE
Linearserv Drive Connections
6K Connections
Signal Name
Connector
Pin
Signal Name Connector
Pin
Step +
CN1
15
↔
Step +
DRIVE
01
Step –
CN1
39
↔
Step –
DRIVE
09
Dir
CN1
13
↔
Dir
DRIVE
02
Direction –
CN1
37
↔
Direction –
DRIVE
10
Servo On –
CN1
05
↔
Ground
DRIVE
13
Servo On +
CN1
01
↔
Shutdown –
DRIVE
12
Servo Ready +
CN1
31
↔
Drive Fault
DRIVE
05
Servo Ready –
CN1
26
↔
Ground
DRIVE
13
A +
CN1
17
↔
A +
ENCODER
02
A –
CN1
41
↔
A –
ENCODER
03
B +
CN1
19
↔
B +
ENCODER
04
B –
CN1
43
↔
B –
ENCODER
05
Z +
CN1
21
↔
Z +
ENCODER
06
Z –
CN1
45
↔
Z –
ENCODER
07
NOTE: These connections assume that the Linearserv is left in its factory default
setting for Position Mode (for accepting step and direction command
signals). Refer to your Linearserv user guide for verification.
CONNECTIONS TO THE PKH130M DRIVE
PKH130 Drive Connections
6K Connections
Signal Name
Pin
Signal Name Connector
Pin
Clock
06
↔
Step –
DRIVE
09
Direction
05
↔
Dir
DRIVE
02
Fault
02
↔
Drive Fault
DRIVE
05
Reset
07
↔
Shutdown –
DRIVE
12
0V
08
↔
Ground
DRIVE
13
NOTE: The PKH130M drive requires a
PULSE
setting of
PULSE8.0
.