Programming Your Application
6-51
590 Series DC Digital Converter
SPEED LOOP
This function block contains parameters
for setting-up the speed loop. The block
is viewed in two menus on the MMI.
SETPOINTS
This MMI menu contains the setpoint
parameter reference inputs for the
function block.
MMI Menu Map
1
SETUP PARAMETERS
2
SPEED LOOP
PROP.
GAIN
INT. TIME CONST.
INT.
DEFEAT
ENCODER
SIGN
SPEED FBK SELECT
MMI Menu Map
1
SETUP PARAMETERS
2
SPEED LOOP
3
SETPOINTS
SETPOINT
1
SIGN 2 (A3)
RATIO 2 (A3)
SETPOINT 2 (A3)
SETPOINT
3
SETPOINT
4
MAX
DEMAND
MIN
DEMAND
SPEED LOOP
–
OUTPUT [356]
–
0.00%
–
SPEED FEEDBACK [207]
–
0.00%
–
SPEED SETPOINT [ 63]
–
0.00%
–
SPEED ERROR [297]
–
0.00%
10.00
–
[ 14] PROP. GAIN
–
0.500 SECS
–
[ 13] INT. TIME CONST.
–
OFF
–
[202] INT. DEFEAT
–
POSITIVE
–
[ 49] ENCODER SIGN
–
ARM VOLTS
–
[ 47] SPEED FBK SEL
–
0.00%
–
[289] SETPOINT 1
–
POSITIVE
–
[ 9] SIGN 2 (A3)
–
1.0000
–
[ 7] RATIO 2 (A3)
–
–
SETPOINT 2 (A3) [290]
–
0.00%
0.00%
–
[291] SETPOINT 3
–
0.00%
–
[ 41] SETPOINT 4
–
105.00%
–
[357] MAX DEMAND
–
-105.00%
–
[358] MIN DEMAND
–
Parameter Descriptions
PROP. GAIN
Range:
ENABLED/DISABLED
Speed loop PI proportional gain adjustment.
INT. TIME CONST.
Range: 0.001 to 30.000 SECS
Speed loop PI integral gain adjustment.
INT. DEFEAT
Range:
ON/OFF
Inhibits the integral part of the speed loop PI control to give proportional only control.
ENCODER SIGN
Range:
POSITIVE/NEGATIVE
Since the encoder feedback cannot be reversed electrically, the signal polarity can be reversed by
the control software.
SPEED FBK SELECT
Range: See below
Four options are available:
i)
Armature voltage feedback
ARM
VOLTS
ii)
Analog tachogenerator feedback
ANALOG
TACH
iii) Encoder
feedback
ENCODER
iv)
Analog / Encoder feedback
ENCODER
/
ANALOG
SETPOINT 1
Range: -100.00 to 100.00 %
Speed Setpoint 1 (Default Setpoint Sum 1 O/P).
SIGN 2 (A3)
Range:
POSITIVE/NEGATIVE
Speed Setpoint 2 Sign.
Содержание 590 series
Страница 12: ...605 Frequency Inverter HA389591 Issue 1 Contents Contents Page Cont 12...
Страница 16: ...1 4 Getting Started 590 Series Digital Converter...
Страница 22: ...2 6...
Страница 43: ...Installing the Converter 3 21 590D DC Digital Converter HA467078 Figure 3 6 110A 150A Stack Assembly...
Страница 44: ...3 22 Installing the Converter 590D DC Digital Converter HA467078 Figure 3 7 180A Stack Assembly...
Страница 45: ...Installing the Converter 3 23 590D DC Digital Converter HA467078 Figure 3 8 270A Stack Assembly...
Страница 46: ...3 24 Installing the Converter 590D DC Digital Converter HA467078 Figure 3 9 360A Stack Assembly...
Страница 47: ...Installing the Converter 3 25 590D DC Digital Converter HA467078 Figure 3 10 450A Stack Assembly...
Страница 48: ...3 26 Installing the Converter 590D DC Digital Converter HA467078 Figure 3 11 720A Stack Outline Drawing...
Страница 49: ...Installing the Converter 3 27 590D DC Digital Converter HA467078 Figure 3 12 720A Stack Outline Drawing...
Страница 64: ...3 42 Installing the Converter 590D DC Digital Converter HA467078...
Страница 82: ...4 18 Operating the Converter 590 Series DC Digital Converter...
Страница 90: ...5 8 The Man Machine Interface MMI 590 Series DC Digital Converter...
Страница 168: ...9 6 Control Loops 590 Series DC Digital Converter...
Страница 222: ...13 14 Standard and Optional Equipment 590 Series DC Digital Converter...
Страница 234: ...15 2 The Default Application 590 Series DC Digital Converter...
Страница 242: ......