![Parker 590 series Скачать руководство пользователя страница 108](http://html2.mh-extra.com/html/parker/590-series/590-series_product-manual_3705605108.webp)
6-18
Programming Your Application
590 Series DC Digital Converter
DIAGNOSTICS
This function block is used to monitor
the status of the drive, internal variables,
and its inputs and outputs.
The Parameter Descriptions table below
describes the parameters contained in
the DIAGNOSTICS function block.
The MMI DIAGNOSTICS Menu listing
on the next page contains all the
parameters in the DIAGNOSTICS
menu. Each parameter is given a
number, i.e. D:32, the thirty-second
entry in the MMI DIAGNOSTICS menu
- many of the functional diagrams in this
chapter refer to diagnostics using this
numbering system.
(Note the reference in brackets where each parameter appears in another function block.)
MMI Menu Map
1
DIAGNOSTICS
D:1
SPEED DEMAND
D:2
SPEED FEEDBACK
D:3
SPEED ERROR
D:4
CURRENT DEMAND
D:5
CURRENT FEEDBACK
D:6
POS. I CLAMP
D:7
NEG. I CLAMP
D:8
ACTUAL POS I LIM
D:9
ACTUAL NEG I LIM
D:10
INVERSE TIME O/P
D:11
AT CURRENT LIMIT
D:12
AT ZERO SPEED
D:13
AT ZERO SETPOINT
D:14
AT STANDSTILL
D:15
STALL TRIP
D:16
RAMPING
D:17
PROGRAM STOP
D:18
DRIVE START
D:19
DRIVE ENABLE
D:20
OPERATING MODE
D:21
FIELD ENABLE
D:22
FIELD DEMAND
D:23
FIELD I FBK.
D:24
FLD. FIRING ANGLE
D:25
ANIN 1 (A2)
D:26
ANIN 2 (A3)
D:27
ANIN 3 (A4)
D:28
ANIN 4 (A5)
D:29
ANIN 5 (A6)
D:30
ANOUT 1 (A7)
D:31
ANOUT 2 (A8)
D:32
START (C3)
D:33
DIGITAL INPUT C4
D:34
DIGITAL INPUT C5
D:35
DIGIN 1 (C6)
D:36
DIGIN 2 (C7)
D:37
DIGIN 3 (C8)
D:38
DIGOUT 1 (B5)
D:39
DIGOUT 2 (B6)
D:40
DIGOUT 3 (B7)
D:41
RAISE/LOWER O/P
D:42
PID OUTPUT
D:43
PID CLAMPED
D:44
PID ERROR
D:45
SPT SUM 1 OUTPUT
D:46
RAMP OUTPUT
D:47
SPEED SETPOINT
D:48
TERMINAL VOLTS
D:49
BACK EMF
D:50
TACH INPUT (B2)
D:51
ENCODER
DIAGNOSTICS
–
SPEED FEEDBACK [207]
–
0.00%
–
SPEED ERROR [297]
–
0.00%
–
CURRENT DEMAND [299]
–
0.00%
–
CURRENT FEEDBACK [298]
–
0.00%
–
POS. I CLAMP [ 87]
–
0.0%
–
NEG. I CLAMP [ 88]
–
0.0%
–
ACTUAL POS I LIM [ 67]
–
0.0%
–
ACTUAL NEG I LIM [ 61]
–
0.0%
–
DRIVE START [ 82]
–
OFF
–
DRIVE ENABLE [ 84]
–
DISABLED
–
FIELD I FBK. [300]
–
0.00%
–
TACH INPUT (B2) [308
–
0.0%
–
ENCODER [206]
–
0 RPM
Parameter Descriptions
SPEED FEEDBACK
Range: -300.00% to 300.00%
Speed loop feedback.
(Refer to SPEED LOOP, page 6-51)
SPEED ERROR
Range: -300.00% to 300.00%
Speed loop error.
(Refer to SPEED LOOP, page 6-51)
CURRENT DEMAND
Range: -300.00% to 300.00%
Current loop demand (speed error PI output or external current demand clamped by all the
current limits).
(Refer to CURRENT LOOP, page 6-14)
CURRENT FEEDBACK
Range: -300.00% to 300.00%
Scaled and filtered armature current.
(Refer to CURRENT LOOP, page 6-14)
POS. I CLAMP
Range: -200.0% to 200.0%
Positive current clamp.
(Refer to CURRENT LOOP, page 6-14)
NEG. I CLAMP
Range: -200.0% to 200.0%
Negative current clamp.
(Refer to CURRENT LOOP, page 6-14)
ACTUAL POS I LIM
Range: -200.0% to 200.0%
Overall positive current limit value.
(DIAGNOSTIC only)
ACTUAL NEG. I LIM
Range: -200.0% to 200.0%
Overall negative current limit value.
(DIAGNOSTIC only)
DRIVE START
Range:
ON/OFF
Controller start/run command.
(DIAGNOSTIC only)
DRIVE ENABLE
Range:
ENABLED/DISABLED
Drive speed and current loop are enabled/quenched.
(DIAGNOSTIC only)
FIELD I FBK.
Range: -300.00% to 300.00%
Scaled field current feedback.
(Refer to
CALIBRATION, page 6-11)
TACH INPUT (B2)
Range: -300.00% to 300.00%
Scaled analog tachogenerator feedback.
(Refer to
CALIBRATION, page 6-11)
ENCODER
Range: 0 RPM to 6000 RPM
Encoder speed feedback in RPM.
(Refer to
CALIBRATION, page 6-11)
Содержание 590 series
Страница 12: ...605 Frequency Inverter HA389591 Issue 1 Contents Contents Page Cont 12...
Страница 16: ...1 4 Getting Started 590 Series Digital Converter...
Страница 22: ...2 6...
Страница 43: ...Installing the Converter 3 21 590D DC Digital Converter HA467078 Figure 3 6 110A 150A Stack Assembly...
Страница 44: ...3 22 Installing the Converter 590D DC Digital Converter HA467078 Figure 3 7 180A Stack Assembly...
Страница 45: ...Installing the Converter 3 23 590D DC Digital Converter HA467078 Figure 3 8 270A Stack Assembly...
Страница 46: ...3 24 Installing the Converter 590D DC Digital Converter HA467078 Figure 3 9 360A Stack Assembly...
Страница 47: ...Installing the Converter 3 25 590D DC Digital Converter HA467078 Figure 3 10 450A Stack Assembly...
Страница 48: ...3 26 Installing the Converter 590D DC Digital Converter HA467078 Figure 3 11 720A Stack Outline Drawing...
Страница 49: ...Installing the Converter 3 27 590D DC Digital Converter HA467078 Figure 3 12 720A Stack Outline Drawing...
Страница 64: ...3 42 Installing the Converter 590D DC Digital Converter HA467078...
Страница 82: ...4 18 Operating the Converter 590 Series DC Digital Converter...
Страница 90: ...5 8 The Man Machine Interface MMI 590 Series DC Digital Converter...
Страница 168: ...9 6 Control Loops 590 Series DC Digital Converter...
Страница 222: ...13 14 Standard and Optional Equipment 590 Series DC Digital Converter...
Страница 234: ...15 2 The Default Application 590 Series DC Digital Converter...
Страница 242: ......