The 404XE positioner can be mounted in a normal, side, vertical, or inverted orientation. For vertical (Z axis)
mounting, care must be taken since certain ballscrew and load combinations can backdrive in a power loss
situation. For all orientations, the cables should be secured as to not interfere with the movement of the car-
riage.
Chapter 4
-
Setup and Usage
Mounting Orientation
Normal
Side
Vertical
Inverted
Mounting Surface Requirements
Proper mounting of the 404XE positioner is essential to optimize product performance. All specifications are
based on the following conditions:
•
The positioner must be bolted down along its entire length.
•
The positioner must be mounted to a flat, stable surface with flatness error less than or equal to
0.013mm/300mm
(0.0005”/
ft).
•
Catalog specifications may deviate for a positioner mounted to a surface that does not meet the above
conditions.
•
If the surface does not meet the above conditions the surface may be shimmed to comply with these re-
quirements.
•
If mounting conditions require that the table base be overhung, catalog specifications will not be met over
that portion of the table. Additionally, in X
-
Y systems the overhung portion of the Y axis may not meet
specifications due to the additional error caused by deflection of the unsupported base. Contact factory
for guidelines on specifications of overhung applications.