Parameter Reference
15-1
AC10 Inverter
Chapter 15
Parameter Reference
15.1 Basic parameters: F100-F160
Function
Code
Function
Definition
Setting Range
Mfr’s Value Change
F100
User’s Password
0
~
9999
√
F102
Inverter’s Rated Current (A)
Subject to
inverter model
○
*
F103
Inverter Power (kW)
Subject to
inverter model
○
*
F104
Reserved
F105
Software Edition No.
Subject to
inverter model
△
F106
Control Mode
Setting range:
0:Sensorless vector control
(SVC);
1: Reserved;
2: VVVF
3: Vector control 1
6: PMSM sensorless vector
control
2
╳
F107
Password Valid or Not
0: invalid; 1: valid
0
√
F108
Setting User’s Password
0
~
9999
8
√
F109
Starting Frequency (Hz)
0.0
~
10.00Hz
0.0
√
F110
Holding Time of Starting Frequency (S)
0.0
~
999.9
0.0
√
F111
Max Frequency (Hz)
F113
~
590.0Hz
50.00
√
F112
Min Frequency (Hz)
0.00Hz
~
F113
0.50
√
F113
Target Frequency (Hz)
F112
~
F111
50.00
√
F114
1
st
Acceleration Time (S)
0.1
~
3000
subject to
inverter
model
√
F115
1
st
Deceleration Time (S)
0.1
~
3000
√
F116
2
nd
Acceleration Time (S)
0.1
~
3000
√
F117
2
nd
Deceleration Time (S)
0.1
~
3000
√
F118
Base Frequency (Hz)
15.00
~
590.0
50.00
╳
F119
Reference of Setting Accel/Decel Time
0: 0~50.00Hz
1: 0~ F111
0
╳
F120
Forward/Reverse Switchover Dead-Time
0.0
~
3000
0.0
√
F121
Reserved
F122
Reverse Running Forbidden
0: invalid; 1: valid
0
╳
F123
Minus Frequency is Valid in the Mode of Combined
Speed Control.
0
:
Invalid
;
1
:
valid
0
╳
F124
Jogging Frequency
F112
~
F111
5.00Hz
√
F125
Jogging Acceleration Time
0.1
~
3000S
subject to
inverter
model
√
F126
Jogging Deceleration Time
0.1
~