TG-Filter_EN_01—2016
21
►
Make sure during assembly that
—
the O-rings are properly seated
—
the grease does not come into contact with O-rings and sealing surfaces.
Both housing parts have marking arrows.
►
Connect both housing parts again and hand-tighten them until the marking
arrows match.
►
Close the manual drain valve again.
►
For ATEX-compliant filters:
Ensure conductivity, test and document it.
►
Check the housing for tightness.
Check well running of threads
There is a risk of threads seizing when a filter made of aluminium, steel or
stainless steel is stored.
►
Make the same preparations as described in section “Preparations” on
page 17.
►
Open the filter at regular intervals, e.g. every 6 months.
►
Check whether the threads are still sufficiently greased and well running.
►
Apply a thin coat of grease on the housing threads before assembly if
necessary. Use only TG 1 thread grease unless any other grease has been
agreed upon in the order!
►
Connect both housing parts again.
►
For ATEX-compliant filters:
Ensure conductivity, test and document it.
►
Check the housing for tightness.
Disposing of filter elements and cartridges
The filter element or cartridge might be contaminated by the filtered substances.
Heed the notes on hazardous substances for the filtered gas and applicable
disposal regulations when disposing.
You can obtain the waste code number for the used materials from the
manufacturer.