Maintenance intervals and work
Hazard due to a sudden release of pressure!
Never remove any parts of the filter, or manipulate the same in any way,
for as long as the filter is still pressurised! A sudden escape of pressure
may cause serious injuries.
Depressurise the filter before carrying out any work on the filter.
Danger due to release of a critical gas!
The release of a critical (explosive, flammable, poisonous) gas from the
network can constitute a considerable risk for man and environment.
Therefore heed the following before working on filters for critical gases
— flush the pipe section in question with inert gas
— have the notes on hazardous substances for the used gas ready
— take appropriate protection measures
— verify the absence of an explosive atmosphere
Maintenance intervals
Maintenance interval
Component/series
Action
1
2
3
4
5
Manual drain valve
Drain condensate
x
Entire filter
Clean
x
Earthing lugs
Retighten
x
TGA1, TGH1, TGE3 series:
Housing
Check well running of
threads
x
S, P, C, CF, CSF, HTNX, HTCR, PL
Replace the filter element
x
Housing
Replace O-ring or flat seal
x
TGA1, TGH1 series:
TKA, TKM, CS, OX, SG cartridge
Renew cartridge
x
1 = Daily
2 = Weekly
3 = Every 6 months
4 = Every year (regardless of operating hours), at the latest with a
differential pressure of 0.35 bar (0.6–0.8 bar for a high pressure filter)
5 = Depending on the load or to be determined by measuring