Available options
16
HDK-MT350_EN_04
Available options
The following options are available for the dryer:
Start-up device
Auxiliary heater
Bypass line
Signalling contacts of control system
Compressor synchronisation
Dewpoint-sensing control
Condensate drain pipe for preliminary and afterfilter
Pressure maintaining valve (also: start-up device)
A pressure maintaining valve is implemented downstream of the dryer. It ensures
fast pressure build-up and prevents pressure spikes in the drying agent bed. This
also prolongs the drying agent service life. A pressure maintaining valve must be
installed. The operator can either purchase and have the pressure maintaining
valve installed from the manufacturer or assign installation to an authorised fitter.
Auxiliary heater
For installation sites with temperatures under +1 ºC (33,8 °F), the wet side of the
dryer must be equipped with an auxiliary heater to prevent valves, cocks, flaps,
and other components from freezing up.
Bypass line
The bypass line is a "detour line", which allows the compressed air system to
continue operating even whilst maintenance of the dryer is in progress. However,
during this time the air is not dried but flows through the bypass line past the
dryer and through to the actual loads. Filters in the bypass line are meaningful so
that the actual loads are largely protected against dirt, water, and oil droplets
even whilst maintenance is in progress.
Signalling contacts of the control system
The control system is equipped with a digital input for the synchronised operation
with a compressor. This feature allows for synchronised and thus efficient dryer
operation with discontinuous compressor operation.The control system can also
be equipped with an optional operation signalling contact with which the dryer
operation can be monitored from an external device.
Compressor synchronisation
Compressor synchronisation helps reduce energy costs, as the dryer can be
operated independently of the compressor. When the compressor is switched off,
the regeneration gas return ensures that regeneration is continued, as soon as a
certain compressed air volume is reached behind the dryer. The regeneration
process must be continued and ended so that the drying agent does not become
unusable prematurely.
The compressor synchronisation controller is a higher-level controller than the
pressure dew point controller (see below). When both options are in place, the
compressor synchronisation controller is treated as the prime controller.
Содержание HDK-MT 10-100
Страница 1: ...High Pressure Dryer HDK MT 4 100 70 350 Operating Instructions Revision 04 2014 EN ...
Страница 6: ...Manufacturer s details 6 HDK MT350_EN_04 General information Manufacturer s details Name and address ...
Страница 52: ...Logic control diagram 52 HDK MT350_EN_04 Logic control diagram Adsorption in B1 and regeneration in B2 ...