For your own safety
HDK-MT350_EN_04
13
Maintenance of the dryer and fault removal
Hazard due to a sudden release of pressure!
Never remove any parts of the dryer, or manipulate the same in any way,
for as long as the plant is still pressurised! A sudden escape of pressure
may cause serious injuries.
Before carrying out any work on the dryer, first depressurise the plant.
Carry out maintenance work only when the plant has been shut down and
depressurised!
The factory settings on the control board in the switchbox must not be
changed on any account without prior approval by the manufacturer.
Bolt connections must be undone with care! Note ram pressure values!
Otherwise emerging media may cause personal injury.
Never carry out any welding on a vessel or change the same in any other
way!
Never use pipes and fittings as steps or holding points! The components
might fracture, or the distortions which occur may cause internal damage on
the dryer. There is a risk of injury by slipping off the components,
components breaking off, and expanding compressed air!
Never leave tools, loose parts or cloths in, at or on the dryer.
Following maintenance work always test all flange and bolt connections for
leak tightness and secure seating.
Only use replacement parts that are suitable for the relevant function and
meet the technical requirements stipulated by the manufacturer. This is
always the case, if you use original replacement parts only.
Disassembly and disposal
Hazard due to a sudden release of pressure!
Never remove any parts of the dryer, or manipulate the same in any way,
for as long as the plant is still pressurised! A sudden escape of pressure
may cause serious injuries. Before carrying out any work on the dryer,
first depressurise the plant.
Dispose all parts of the dryer, the drying agent, and all other operating
materials in an environmentally safe way and in accordance with all current
statutory regulations. The waste code numbers of the drying agents can be
obtained from the manufacturer (for the manufacturer's address see page 6).
Содержание HDK-MT 10-100
Страница 1: ...High Pressure Dryer HDK MT 4 100 70 350 Operating Instructions Revision 04 2014 EN ...
Страница 6: ...Manufacturer s details 6 HDK MT350_EN_04 General information Manufacturer s details Name and address ...
Страница 52: ...Logic control diagram 52 HDK MT350_EN_04 Logic control diagram Adsorption in B1 and regeneration in B2 ...
Страница 53: ...Annex with technical documentation HDK MT350_EN_04 53 Regeneration in B1 and adsorption in B2 ...