Start-up
HDK-MT350_EN_04
27
Setting times of the operating phases
In its standard version the dryer is delivered with a time-dependent control
system. The phase sequence occurs in a fixed cycle.
With the optional dewpoint-sensing control, the dryer can also be operated at
variable cycles (depending on the dewpoint).
The following table provides information on the duration of the individual phases.
Phase duration
Fixed cycle
Variable cycle
Adsorption
10 min
60 min, maximum
Regeneration, total
10 min
10 min
−
of which: expansion time
~ 0.2 min
~ 0.2 min
−
of which: dehumidification time
~ 8 min
~ 8 min
−
of which: pressure build-up
~ 2 min
~ 2 min
Standby
—
~ 50 min, maximum
Overview of operating and control elements
ON/OFF switch
The ON/OFF switch (2) is located to the side of the control cabinet and above the
mains plug (1, see figure):
If it is set to
0
, the power supply is disconnected and the dryer is switched off.
The main and expansion valves are normally closed. This ensures that the
main flow direction is blocked when the dryer is switched off.
If the switch is set to
I
, the dryer is switched
on and begins to operate in fixed cycle mode
(i.e. time-controlled).
If the switch is set to position
II
, the dryer is
switched on and begins to operate
—
with compressor synchronisation
—
in variable cycle mode (i.e. dew-point-
controlled).
Position
II
is only relevant for operation with
the optional
compressor synchronisation
and/or
dewpoint-sensing control
.
Control cabinet with ON/OFF switch
Содержание HDK-MT 10-100
Страница 1: ...High Pressure Dryer HDK MT 4 100 70 350 Operating Instructions Revision 04 2014 EN ...
Страница 6: ...Manufacturer s details 6 HDK MT350_EN_04 General information Manufacturer s details Name and address ...
Страница 52: ...Logic control diagram 52 HDK MT350_EN_04 Logic control diagram Adsorption in B1 and regeneration in B2 ...
Страница 53: ...Annex with technical documentation HDK MT350_EN_04 53 Regeneration in B1 and adsorption in B2 ...