Warning

Read and follow these warnings and the instructions that follow. Failure to do so could 

result in serious property damage and/or serious bodily injury.

• Use and maintenance of the PANELLIFT

®

 Drywall

Lift shall be limited to authorized personnel who are

trained in the proper techniques for its safe operation

and maintenance and who are familiar with the various

hazards of overhead material handling.

• As with any lifting equipment, 

ALWAYS WEAR A HARD

HAT

 when operating the PANELLIFT

®

 Drywall Lift and

keep children away from the work area. Failure to do so

could result in serious bodily injury.

DO NOT

 ATTEMPT TO USE YOUR PANELLIFT

®

Drywall Lift IF ANY PART IS MISSING, DAMAGED OR

WORN. ORDER A REPLACEMENT PART IMMEDIATELY.

Using a PANELLIFT

®

 Drywall Lift with missing, damaged

or worn components can result in failure of the unit and

possibly severe property damage and/or serious bodily

injury.

INSPECT THE CHAIN ASSEMBLIES BEFORE EACH

USE. REPLACE AT THE FIRST SIGN OF DAMAGE OR

WEAR.

 A worn, damaged or improperly installed chain

can fail resulting in a sudden and rapid lowering of the

lift and the load and possibly resulting in serious property

damage and/or serious bodily injury. Inspect the chains

by extending the lift fully and examining the full length of

each lift chain for signs of damage or wear.

The weight capacity of the PANELLIFT

®

 Drywall Lift

is 150 lbs. (68 kg). DO NOT load the unit beyond this

limit. When loading wallboard (or similar building

panels), load only one sheet of wallboard at a time.

Failure to follow this warning can result in an unstable load

and/or damage to the PANELLIFT

®

 Drywall Lift contributing

to a sudden failure of the machine and serious property

damage and/or serious bodily injury.

DO NOT TAMPER WITH OR ADJUST

 the setting of

the hydraulic pump on the PANELLIFT

®

 Drywall Lift.  This

is factory preset for the load range of the intended use

of the lift. Altering this factory setting can subject the

components of the lift to stresses and loads that they

were not designed to carry.  This can result in failure of

the unit which may include a sudden and rapid lowering

of the lift and the load possibly resulting in serious property 

damage and/or serious bodily injury.

DO NOT ROLL

 a loaded PANELLIFT

®

 Drywall Lift while

the load is raised. Always keep the load lowered until the

lift is in place beneath the space in which the load will be

installed. Rolling a PANELLIFT

®

 Drywall Lift while the load

is raised can result in tipping the lift and load possibly

resulting in serious property damage and/or serious bodily

injury.

• Operate the PANELLIFT

® 

Drywall Lift only on hard, flat,

level surfaces free of obstructions, debris, clutter, pits, holes

or openings. Failure to follow this warning can result in tip-

ping the lift and/or load possibly resulting in serious prop-

erty damage and/or serious bodily injury.

• The PANELLIFT

®

 Drywall Lift is designed exclusively as

a material lift and shall be used for no other purpose. The

PANELLIFT

®

 Drywall Lift is not a personnel lift or platform

and shall not be used as such. Using the PANELLIFT

®

Drywall Lift for purposes other than a material lift can

subject the unit to stresses and loads that it was not

designed to carry.  This can result in failure of the unit

which may include a sudden and rapid lowering of the lift

and the load possibly resulting in serious property damage

and/or serious bodily injury.

• The PANELLIFT

®

 Drywall Lift is made of steel which

conducts electricity. Keep the unit away from live electrical

wires. Failure to do so could result in electrocution.

• Use only factory authorized replacement parts. Installation

of other parts can compromise the safe design of the

PANELLIFT

®

 Drywall Lift and may cause failure of the

unit possibly resulting in serious property damage and/or

serious bodily injury.

• Moving the PANELLIFT

®

 Drywall Lift from a cold

environment to a warm one may cause condensation to

form on metal surfaces creating a potential for malfunction.

Such malfunction could possibly result in serious property

damage and/or serious bodily injury: Allow the unit to reach

working room temperature before operating.

Keep

 hands, hair, and clothing away from chains and

movable telescoping sections.

• BEFORE

 operating this equipment, thoroughly read

this set of instructions, make sure you understand them,

and only then follow the step-by-step directions.

FAILURE TO READ AND FOLLOW THESE

INSTRUCTIONS 

could result in failure of the

equipment. Failure of the equipment while the lift is

raised can include a sudden and rapid lowering of

the lift and load possibly resulting in serious property

damage and/or serious bodily injury.

Questions?

 - Call 

Paragon Pro Manufacturing Solutions

 Customer Service at 1-800-448-0822 or 701-775-0551

- 1 -

Содержание Telpro PanelLift 460

Страница 1: ...NING For Model 460 Before operating this equipment thoroughly read this set of instructions make sure you understand them and only then follow the step by step directions Failure to do so could result...

Страница 2: ...t We take pride in providing the best for our customers Quality innovation and excellence are all qualities this company ensures No product is sent without being factory tested and inspected to ensure...

Страница 3: ...ents Product Specifications Page 3 Assembly Pages 4 7 Operation Page 8 Disassembly Pages 9 10 Parts Index Care Maintenance Pages 11 12 Safety Page 16 CONTENTS ALL PHOTOS ARE FOR ILLUSTRATIVE PURPOSES...

Страница 4: ...load is raised Always keep the load lowered until the lift is in place beneath the space in which the load will be installed Rolling a PANELLIFT Drywall Lift while the load is raised can result in ti...

Страница 5: ...s injury and or property damage As with any lifting equipment always WEAR A HARD HAT when operating unit The load rating of the PANELLIFT Brand Wallboard Lift is 150 lbs DO NOT load the unit beyond th...

Страница 6: ...ad Rating 150 lbs 68 kg DO NOT EXCEED Maxi mum Height 15 457 cm 16 6 503 cm with optional 18 extension Lo ading Height 40 102 cm Net Weig ht Approximately 180 lbs 82 kg Power Source 12 volt DC hydraul...

Страница 7: ...BEGIN BY SETTING UP THE TRIPOD BASE PRESS DOWN ON THE SLIDE YOKE PIN CLIP AND SWING THE OUTER LEGS OUT UNTIL THEY LOCK IN THE WORKING POSITION NOTE THE HOLES ON THE BOTTOM OF THE SLIDE TUBE 3 PLACE T...

Страница 8: ...ED PLATE AND TAPERED SLOT ALIGN UNTIL THE PLATE BOTTOMS OUT AND LOCKS IN PLACE 7 A ATTACH THE HYDRAULIC HOSE QUICK CONNECTOR FEMALE TO THE MALE CONNECTOR ON THE FRAME B IF PRESSURE HAS BEEN APPLIED TO...

Страница 9: ...DRYWALL ON SIDEWALLS AND SLOPED CEILINGS ASSEMBLY continued 6 8 OPEN POWER BOX AND CONNECT BATTERY USING EASY CONNECT WIRING HARNESS 11 PLACE THE TAPERED PLATES OF THE CROSS ARMS INTO THE TAPERED SOCK...

Страница 10: ...DO NOT USE THE PANELLIFT WITH THE OUTRIGGERS EXTENDED BEYOND THE 33 POINT RETRACT THE OUTRIGGERS WHEN STORING OR TRANSPORTING THE UNIT 13 THE 460 IS EQUIPPED WITH ITS OWN BUILT IN CHARGING UNIT PLUG I...

Страница 11: ...ift first when stopping to avoid having the lift jump slightly at the end of the retraction 1 TO LOAD Set the backsotp on the tripod base to hold the unite in position Extend the cradle outriggers to...

Страница 12: ...THE RETAINING CAP AS SHOWN ALWAYS CLOSE THE TELESCOPING SECTION RETAINING CAP WHEN TRANSPORTING UNIT FAILURE TO DO SO WILL ALLOW THE TELESCOPING SECTIONS TO EXTEND FREELY CAUSING SLACK IN THE CHAINS...

Страница 13: ...TO REMOVE THE POWER BOX PRESS AND HOLD THE RELEASE TAB AS SHOWN WITH ONE HAND WHILE LIFTING THE BOX OFF THE FRAME WITH THE OTHER 6 LIFT THE FRAME OFF THE TRIPOD BASE Push 10 7 TO FOLD THE TRIPOD BASE...

Страница 14: ...ARTS INDEX Model 460 11 1 06 1 07 1 20 1 03 1 05 1 17 1 18 26 01 25 01 25 00 28 08 28 01 28 06 28 07 28 00 1 00 29 04 29 01 25 04 26 06 26 00 27 00 26 02 26 03 29 05 29 02 25 01 29 00 29 06 29 04 29 1...

Страница 15: ...on 1 07 Outrigger with end caps 1 10 Cradle tilt latch 1 17 Complete mounting head assembly 1 18 Complete mounting head spring kit 1 20 Cradle body CARE MAINTENANCE Inspect chains FREQUENTLY A t least...

Страница 16: ...e Chloride Dichloromethane Cancer 75 09 2 Trace Nickel Cancer 7440 02 0 Trace Propylene glycol monobutyl ether Cancer 5131 66 8 Trace Toluene Developmental 108 88 3 Trace Carbon Black Cancer 1333 86 4...

Страница 17: ...Questionsabout assembly Can t find a part Need some other help Call us 1 800 448 0822 701 775 0551 We ll get you set up...

Отзывы: