Worksheets
A-2
7914-A2-GB20-00
February 1998
DSX-1-to-DSX-1 Configuration
Multiplexer
DSX-1 Unit
T1
Multiplexer
T1
Cross-campus
2-wire facility
Customer Premises
Central Site
97-15718
DSX-1 Unit
To connect two DSX-1-compatible units, configure the units as follows. Terminal
Mode factory defaults are in bold (for Switchpack mode defaults, see
Appendix C,
Switchpack Definitions
).
Configuration
Option
DSX-1-Compatible Unit
(Customer Premises)
DSX-1-Compatible Unit
(Central Site)
Card Type
CP (default)
CO
T1 Line Encoding
B8ZS or AMI
Must be same as CP side
Framing
D4, Extended Superframe,
or Unframed
Must be same as CP side
Line Build-Out
Enter 4 at the Config
command prompt. Select
from the following options:
1) 0 to 133 ft
2) 133 to 266 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 655 ft
Enter 4 at the Config command
prompt. Select from the following
options:
1) 0 to 133 ft
2) 133 to 266 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 655 ft