Monitoring the Unit
6-4
7914-A2-GB20-00
February 1998
For example, pressing 1 at the stats prompt yields a screen like the following:
stats
→
1
Current 1 minute:
SDSL Errors:
T1 Errors:
FAW –
0
BPV – 0
CRC –
0
MOS –
0
FEBE –
0
FAS –
0
(D4 framing only)
CRC –
0
(ESF framing only)
Previous 1 minute:
SDSL Errors:
T1 Errors:
FAW –
0
BPV –
0
CRC –
0
MOS –
0
FEBE –
0
FAS –
0
(D4 framing only)
CRC –
0
(ESF framing only)
stats
→
Performance statistics have a maximum value of 65,536. If the maximum
value is reached, the statistic resets to zero.
Performance statistics are updated every second.
T1 Errors (BPV, MOS, FAS, and CRC) are only displayed for
DSX-1-compatible units that are operating in framed mode.
Interface
Counter
Meaning
SDSL
FAW
Frame Alignment Word. Loss of synchronization
was detected.
CRC
Cyclic Redundancy Check. An invalid CRC value
was detected.
FEBE
Far End Bit Error. An error was reported by the
remote equipment.
T1
BPV
Bipolar Violation. Two consecutive pulses of the
same poalrity were detected.
MOS
Multiframe Out of Sync. Loss of synchronization
was detected.
FAS
Frame Alignment Signal. A loss of signal was
detected. (Shown only when Framing is set to D4.)
CRC
Cyclic Redundancy Check. An invalid CRC value
was detected. (Shown only when Framing is set to
ESF.)