5. Operation and Maintenance
9123-A2-GB20-20
August 2001
5-27
Clearing Performance Statistics
Performance statistics counters can be reset to the baseline when using a
directly-connected asynchronous terminal and your security Access Level
is Level-1. This feature is useful when troubleshooting problems.
Statistic counters are not actually cleared using this feature. True statistic counts
are always maintained so SLAs can be verified, and they can be viewed from an
SNMP NMS. However, since statistics can be cleared locally, the statistics viewed
via the menu-driven user interface may be different from those viewed from the
NMS.
Procedure
To clear all statistics:
Performance Statistics
→
Clear All Statistics
Procedure
To clear specific sets of statistics:
Use the ClrSLV&DLCIStats function key to reset the SLV and DLCI
performance statistic counters for the currently displayed DLCI from one of the
following screens:
Performance Statistics
→
Service Level Verification
Performance Statistics
→
DLCI
Use the ClrLinkStats function key to reset the frame relay link performance
statistics.
Performance Statistics
→
Frame Relay
Use the ClrNearStats or ClrFarStats function key to reset all near-end or all
far-end Extended SuperFrame (ESF) line performance statistics.
Performance Statistics
→
ESF Line
Содержание FrameSaver FLEX 9123
Страница 1: ...FrameSaver FLEX 9123 User s Guide Document No 9123 A2 GB20 20 August 2001 ...
Страница 10: ...Contents viii August 2001 9123 A2 GB20 20 ...
Страница 24: ...1 About the FrameSaver FLEX 9123 1 10 August 2001 9123 A2 GB20 20 ...
Страница 34: ...2 User Interface and Basic Operation 2 10 August 2001 9123 A2 GB20 20 ...
Страница 98: ...3 Configuration 3 64 August 2001 9123 A2 GB20 20 ...
Страница 194: ...7 Setting Up OpenLane for FrameSaver Devices and Activating SLV Capability 7 10 August 2001 9123 A2 GB20 20 ...
Страница 212: ...8 Setting Up NetScout Manager Plus for FrameSaver Devices 8 18 August 2001 9123 A2 GB20 20 ...
Страница 228: ...A Menu Hierarchy A 6 August 2001 9123 A2 GB20 20 ...
Страница 258: ...B SNMP MIBs and Traps and RMON Alarm Defaults B 30 August 2001 9123 A2 GB20 20 ...
Страница 266: ...C Connectors Cables and Pin Assignments C 8 August 2001 9123 A2 GB20 20 ...