DLCI Alarm Defaults – NetScout Area
These alarms can be created during RMON initialization or when a DLCI is
created. They are put into the NetScout alarm area.
Table B-12, Static DLCI Alarm Defaults – NetScout Area
, identifies alarm
defaults that do not change.
Table B-13, Dynamic DLCI Alarm Defaults – NetScout Area
, identifies alarm
defaults that change when the interface’s line speed changes.
The thresholds for these alarms can be edited using NetScout Manager Plus so
they match the values in the SLA between the customer and service provider. Up
to eight alarms per interface are allowed. Any additional alarms are added to the
Paradyne Area alarms and they cannot be changed using NetScout software.
See
Setting Up NetScout Manager Plus for
Table B-12. Static DLCI Alarm Defaults – NetScout Area (1 of 2)
Item
Sample
Type
1
MIB/Tag/OID
2
Interval
Event
Type
Rising
Threshold
Default
Falling
Threshold
Default
Current Latency
A
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLatencyLatest
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.3.1.7.I.D
60 secs
(1 min)
None
Must be
configured.
0
Average Latency
A
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLatencyAvg
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.3.1.5.I.D
900 secs
(15 mins)
None
Must be
configured.
0
Frames Received
D
MIB: FR DTE MIB (RFC 2115)
Tag: frCircuitReceivedFrames
OID: .1.3.6.1.2.1.10.32.2.1.
8.I.D
60 secs
(1 min)
None
Must be
configured.
0
Frames Sent
D
MIB: FR DTE MIB (RFC 2115)
Tag: frCircuitSentFrames
OID: .1.3.6.1.2.1.10.32.2.1.
6.I.D
60 secs
(1 min)
None
Must be
configured.
0
1
D = Delta. Indicates that the calculated difference between the current value and the previous value is
contained in the MIB.
A = Absolute. Indicates that the exact value for the item is contained in the MIB.
2
I in the OID = Interface ID of the frame relay link.
D = DLCI number.
Содержание FrameSaver FLEX 9123
Страница 1: ...FrameSaver FLEX 9123 User s Guide Document No 9123 A2 GB20 20 August 2001 ...
Страница 10: ...Contents viii August 2001 9123 A2 GB20 20 ...
Страница 24: ...1 About the FrameSaver FLEX 9123 1 10 August 2001 9123 A2 GB20 20 ...
Страница 34: ...2 User Interface and Basic Operation 2 10 August 2001 9123 A2 GB20 20 ...
Страница 98: ...3 Configuration 3 64 August 2001 9123 A2 GB20 20 ...
Страница 194: ...7 Setting Up OpenLane for FrameSaver Devices and Activating SLV Capability 7 10 August 2001 9123 A2 GB20 20 ...
Страница 212: ...8 Setting Up NetScout Manager Plus for FrameSaver Devices 8 18 August 2001 9123 A2 GB20 20 ...
Страница 228: ...A Menu Hierarchy A 6 August 2001 9123 A2 GB20 20 ...
Страница 258: ...B SNMP MIBs and Traps and RMON Alarm Defaults B 30 August 2001 9123 A2 GB20 20 ...
Страница 266: ...C Connectors Cables and Pin Assignments C 8 August 2001 9123 A2 GB20 20 ...