3. Configuration
3-48
August 2001
9123-A2-GB20-20
Primary DLCI
Possible Settings: 16 – 1007
Default Setting: Initially blank; no default.
Specifies the DLCI number used for the management PVC after the frame relay interface
is selected.
The DLCI must be defined for the link (i.e., has a DLCI record), and it must not be part of
a PVC connection or already assigned as a management PVC. For multiplexed DLCIs, at
least one EDLCI must be unconfigured for the DLCI.
NOTES:
– DLCI cannot be entered if the Link field is blank.
– Clearing the Link also clears the DLCI.
16 – 1007 – Specifies the DLCI number (inclusive).
Primary EDLCI
Possible Settings: 0 – 62
Default Setting: Initially blank; no default.
Specifies the EDLCI number used for a management PVC when a multiplexed DLCI is
selected. EDLCIs identify individual connections within multiplexed DLCIs that are unique
to those DLCIs.
Use a unique EDLCI to identify an individual connection within a multiplexed DLCI. Use 0
to identify the primary EDLCI. Use 1 – 62 to identify secondary EDLCIs. Use the primary
EDLCI for customer data, which has a higher utilization rate than management data, with
slightly less line overhead.
Display Conditions – This option does not appear if the DLCI field does not reference a
multiplexed DLCI.
NOTE: Clearing the DLCI or changing it to a standard DLCI suppresses EDLCI field.
0 – 62 – Specifies the EDLCI number (inclusive).
Primary Link RIP
Possible Settings: None, Proprietary, Standard_out
Default Setting:
For multiplexed DLCIs: Proprietary
For nonmultiplexed DLCIs: Standard_out
Specifies which Routing Information Protocol (RIP) is used to enable routing of
management between FrameSaver units and attached equipment.
None – Does not use a routing protocol.
Proprietary – Uses a proprietary variant of RIP version 1 to communicate routing
information between FrameSaver units. A FrameSaver unit must be on the other end of
the link. This is the factory default for management PVCs configured on multiplexed DLCIs
(see
Table 3-7, DLCI Record Options
).
Standard_out – The device will send standard RIP messages to communicate routing
information only about FrameSaver FLEX and SLV units in the network. This is the factory
default for management PVCs configured on standard DLCIs.
NOTE: The router must be configured to receive RIP on the port connected to the
FrameSaver unit for the management interface (e.g., Cisco:
config-t,
router RIP, int serial
x, IP RIP Receive version 1, ctl-z WR
). See
Setting Up So the Router Can Receive RIP
Table 3-10. Management PVC Options (3 of 3)
Содержание FrameSaver FLEX 9123
Страница 1: ...FrameSaver FLEX 9123 User s Guide Document No 9123 A2 GB20 20 August 2001 ...
Страница 10: ...Contents viii August 2001 9123 A2 GB20 20 ...
Страница 24: ...1 About the FrameSaver FLEX 9123 1 10 August 2001 9123 A2 GB20 20 ...
Страница 34: ...2 User Interface and Basic Operation 2 10 August 2001 9123 A2 GB20 20 ...
Страница 98: ...3 Configuration 3 64 August 2001 9123 A2 GB20 20 ...
Страница 194: ...7 Setting Up OpenLane for FrameSaver Devices and Activating SLV Capability 7 10 August 2001 9123 A2 GB20 20 ...
Страница 212: ...8 Setting Up NetScout Manager Plus for FrameSaver Devices 8 18 August 2001 9123 A2 GB20 20 ...
Страница 228: ...A Menu Hierarchy A 6 August 2001 9123 A2 GB20 20 ...
Страница 258: ...B SNMP MIBs and Traps and RMON Alarm Defaults B 30 August 2001 9123 A2 GB20 20 ...
Страница 266: ...C Connectors Cables and Pin Assignments C 8 August 2001 9123 A2 GB20 20 ...