5. Operation and Maintenance
5-14
August 2001
9123-A2-GB20-20
Health and Status Messages
The following table provides Health and Status messages that apply to the
FrameSaver 9123 unit.
Table 5-7.
Health and Status Messages (1 of 3)
Message
What It Indicates
AIS at Network
1
An Alarm Indication Signal (AIS) is received by the
network interface. AIS is an unframed, all ones
signal. Possible reasons include:
Upstream FrameSaver unit is transmitting AIS
(keep-alive signal).
The network is transmitting an AIS.
Auto-Configuration Active
Auto-Configuration feature is active, which allows
automatic configuration and cross-connection of
DLCIs as they are reported by the network LMI.
Back-to-Back Mode Active
The operating mode has been configured for
back-to-back operation (
Main Menu
→
Control
→
Change Operating Mode).
The FrameSaver unit can be connected to another
FrameSaver unit without a frame relay switch
between them.
This feature is useful for product demonstrations or
for a point-to-point configuration using a leased line.
CTS down to Port-1 Device
The user data port CTS control lead on the
FrameSaver unit is off.
DLCI
nnnn Down,
frame relay link
The DLCI for the specified frame relay link is down.
DTR Down from Port-1 Device
The DTR control lead from the device connected to
the user data port is deasserted.
EER at Network
1
The error rate of the received network signal
exceeds the currently configured threshold. This
condition only occurs if the network interface is
configured for ESF framing.
This condition clears when the error rate falls below
the threshold value, which may take up to
15 minutes.
Ethernet Link Down
The Ethernet port is enabled, but communication
between the management system and the unit is
not currently possible on the port.
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.
3
Does not apply to a TS Management Link DLCI.
Содержание FrameSaver FLEX 9123
Страница 1: ...FrameSaver FLEX 9123 User s Guide Document No 9123 A2 GB20 20 August 2001 ...
Страница 10: ...Contents viii August 2001 9123 A2 GB20 20 ...
Страница 24: ...1 About the FrameSaver FLEX 9123 1 10 August 2001 9123 A2 GB20 20 ...
Страница 34: ...2 User Interface and Basic Operation 2 10 August 2001 9123 A2 GB20 20 ...
Страница 98: ...3 Configuration 3 64 August 2001 9123 A2 GB20 20 ...
Страница 194: ...7 Setting Up OpenLane for FrameSaver Devices and Activating SLV Capability 7 10 August 2001 9123 A2 GB20 20 ...
Страница 212: ...8 Setting Up NetScout Manager Plus for FrameSaver Devices 8 18 August 2001 9123 A2 GB20 20 ...
Страница 228: ...A Menu Hierarchy A 6 August 2001 9123 A2 GB20 20 ...
Страница 258: ...B SNMP MIBs and Traps and RMON Alarm Defaults B 30 August 2001 9123 A2 GB20 20 ...
Страница 266: ...C Connectors Cables and Pin Assignments C 8 August 2001 9123 A2 GB20 20 ...