Diagnostic Control Panel Messages Reference
C-5
3610-A2-GB91-90
July 1999
Table C-4
(3 of 5)
Device Health and Status Messages
Message
Condition
DSUTst:
test,init
The DSU is running a test, initiated from
init.
test is one of the following tests:
BERT
— Bit Error Rate Test
BiL
— Bilateral Loopback
Dev
— Device Test
DL
— Digital Loopback
DT
— Digital Test
DTE
— DTE Loopback
E-E
— End-to-End Test
Lamp
— Lamp Test
NetL
— Network Loopback (Switched 56 DBM only)
RL
— Remote Digital Loopback
TM
— Test Mode
init is one of the following initiators:
DTE
— Data Terminal Equipment
FP
— Front Panel (the DCP)
LPDA
— NetView-initiated test
NMS
— Network Management System
Ntwk
— Network (Switched 56 DBM only)
Remt
— Remote DSU
External Alarm A
The DSU detects a positive voltage on Pin 23. This alarm condition is defined
by the Ext Leads configuration option.
External Alarm B
The DSU detects a positive voltage on Pin 19. This alarm condition is defined
by the Ext Leads configuration option.
Invalid Address
A DSU was powered up with an invalid address. Invalid addresses are:
0
— This is reserved for the SDU.
192
— This is reserved for the broadcast address.
191
— Invalid for a DSU with a DBM because of the reserved 192
broadcast address.
255
— Invalid for a DSU with a DBM.
>80
— Addresses greater than 80 are not permitted in the DPII protocol.
MCMP CommunicFail
No reply from MCMP circuit card. The DSU periodically polls the MCMP circuit
card for health and status. When the DSU does not receive a response, the
message appears in the Health and Status report.
MUX Device Fail
Internal failure in the TDM or MCMP is detected.
MUX CommunicFail
No reply from TDM circuit card. The DSU periodically polls the TDM circuit card
for health and status. When the DSU does not receive a response, the
message appears in the Health and Status report.
Содержание COMSPHERE 3610
Страница 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices...
Страница 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90...
Страница 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2...
Страница 120: ...COMSPHERE 3600 Series Data Service Units 4 40 July 1999 3610 A2 GB91 90 This page intentionally left blank...
Страница 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90...
Страница 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90...
Страница 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A...
Страница 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90...
Страница 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999...
Страница 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90...
Страница 192: ...COMSPHERE 3600 Series Data Service Units B 2 July 1999 3610 A2 GB91 90 This page intentionally left blank...
Страница 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90...
Страница 246: ...COMSPHERE 3600 Series Data Service Units E 2 July 1999 3610 A2 GB91 90 Figure E 1 Control Channel...
Страница 247: ...Network Management Connectivity E 3 3610 A2 GB91 90 July 1999 Figure E 2 Extended Control Channel...
Страница 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F...
Страница 263: ...Troubleshooting G 3 3610 A2 GB91 90 July 1999 Figure G 2 No Signal NS Condition Troubleshooting...
Страница 265: ...Troubleshooting G 5 3610 A2 GB91 90 July 1999 Figure G 4 Out of Frame OOF Condition Troubleshooting...
Страница 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90...
Страница 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90...
Страница 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90...
Страница 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90...