AIM2-A2-GZ40-20
May 2005
9
NOTE: If you are using a 120 or 180 degree cable, fasten both the top and the
bottom of the RJ21 cable connector to the connector frame on the chassis
using the captive screws.
4-Slot BLC
Subscriber lines must be connected according to the BLC slot in which the
AIM24000 was installed. Interface module slots 1–4 run from bottom to top on the
front of the chassis; the corresponding RJ21 ports are directly behind each slot on
the back of the chassis (1–4, bottom to top). Each interface module slot on the
4000E has two corresponding RJ21 connectors: the connectors on the left (A)
provide the ADSL connection for AIM24000 ports 1-24 and the connectors on the
right (B) provide the ADSL connection for AIM24000 ports 25–48.
For example, if the AIM24000 is installed in Slot 3 of a 4000E, ADSL cables must
be connected to:
RJ21 Connector 3A for AIM24000 ports 1–24
RJ21 Connector 3B for AIM24000 ports 25–48
NOTE: The 4000 BLC has only one RJ21 connector for each interface module
slot. These connectors support ports 1–24 on the AIM24000; ports 25–48 cannot
be connected in a 4000. The 4000E supports all 48 ports.