Power Module LEDs (Model 9820-45M)
Each power module has a green LED which remains lit while power is applied
and the power module is functioning.
When the yellow front panel System PWR LED is lit, one of the power modules
has failed. The failed power module can be identified from the back of the DSU
by its unlit LED.
Table 6-8.
Power Module Troubleshooting
Configuration
Symptom
What to Do
(in order, if problem persists)
One Power
Module
No front panel LEDs are
lit.
1. Verify that the receptacle in use
provides 120 Vac.
2. Verify that the power module switch is
in the On position.
3. Replace the power module. See
Replacing a Power Module
in
Chapter 12,
Hardware Maintenance.
4. Call your service representative.
Two Power
Modules
No front panel LEDs are
lit.
1. Verify that the receptacles in use
provide 120 Vac.
2. Verify that the power module switches
are in the On position.
3. Replace the power modules. See
Replacing a Power Module
in
Chapter 12,
Hardware Maintenance.
4. Call your service representative.
The front panel System
PWR LED is lit.
1. Check the power module LEDs from the
back of the unit and replace the failed
power module (the one whose LED is
off). See
Replacing a Power Module
in
Chapter 12,
Hardware Maintenance.
2. Call your service representative.
Содержание 9820
Страница 10: ...Contents viii 9820 A2 GB20 20 June 2000...
Страница 30: ...User Interface and Basic Operation 2 10 9820 A2 GB20 20 June 2000 This page intentionally left blank...
Страница 98: ...Configuration Options 4 62 9820 A2 GB20 20 June 2000 This page intentionally left blank...
Страница 208: ...Setting Up Network Health for FrameSaver Devices 11 10 9820 A2 GB20 20 June 2000 This page intentionally left blank...
Страница 216: ...Menu Hierarchy A 4 9820 A2 GB20 20 June 2000 This page intentionally left blank...
Страница 246: ...SNMP MIBs and Traps and RMON Alarm Defaults B 30 9820 A2 GB20 20 June 2000...
Страница 266: ...Technical Specifications D 4 9820 A2 GB20 20 June 2000...
Страница 270: ...Equipment List E 4 9820 A2 GB20 20 June 2000 This page intentionally left blank...