Monitoring and Testing
4-13
3163-A2-GB20-10
March 1999
Starting a Repeater Loopback
The Repeater Loopback command (RLB) loops the
signal being sent to the network back to the data port. The
signal is looped back as close to the network interface as
possible (after it has passed through the framing circuitry
of the DSU/CSU). Framing CRCs and BPVs are
corrected.
98-15948
CSU
DSU
NETWORK
INTERFACE
RLB
PORT 1
ALL 1s
"
Procedure
To perform a Repeater loopback:
1. From the top-level menu screen, select Test.
2. From the Test screen, select Lpbk.
F1
Test:
Rlpbk Lpbk
Ptrns
F2
F3
3. From the Loopback screen, press the
key until
the RLB selection appears on the screen.
4. Select RLB.
F1
Loopback:
LLB
PLB
RLB
F2
F3
Test Started appears on Line 2. If a Repeater
loopback is already in progress, the Already
Active message appears. If an invalid combination
of loopbacks is in progress, the error message
Invld Test Combo appears (see
Table 4-5
for
valid loopback test combinations).
Starting a Data Channel Loopback
The Data Channel Loopback command (DCLB) loops
the data received from the network interface, for all DS0
channels allocated to the data port, back to the network.
The loopback occurs after the data passes through the port
circuitry but before it is sent out the data port.
98-16103
CSU
DSU
NETWORK
INTERFACE
DCLB
"
Procedure
To perform a Data Channel loopback:
1. From the top-level menu screen, select Test.
2. From the Test screen, select Lpbk.
F1
Test:
Rlpbk Lpbk
Ptrns
F2
F3
3. From the Loopback screen, press the
key until
the DCLB selection appears on the screen.
4. Select DCLB.
F1
Loopback:
PLB
RLB
DCLB
F2
F3
Содержание 3163
Страница 1: ...ACCULINK 3163 DSU CSU USER S GUIDE Document No 3163 A2 GB20 10 March 1999...
Страница 6: ...ACCULINK 3163 DSU CSU E March 1999 3163 A2 GB20 10...
Страница 22: ...ACCULINK 3163 DSU CSU 2 8 March 1999 3163 A2 GB20 10...
Страница 52: ...ACCULINK 3163 DSU CSU 3 30 March 1999 3163 A2 GB20 10...
Страница 72: ...ACCULINK 3163 DSU CSU 4 20 March 1999 3163 A2 GB20 10...
Страница 74: ...ACCULINK 3163 DSU CSU A 2 March 1999 3163 A2 GB20 10...
Страница 140: ...ACCULINK 3163 DSU CSU G 18 March 1999 3163 A2 GB20 10...
Страница 142: ...ACCULINK 3163 DSU CSU H 2 March 1999 3163 A2 GB20 10...
Страница 150: ...ACCULINK 3163 DSU CSU Glossary 8 March 1999 3163 A2 GB20 10...