Operation
3-9
3163-A2-GB20-10
March 1999
4. From the Select LEDs screen, press the Function
key that corresponds to T1 interface or the data
port for which you want to display LEDs. Use the
scroll keys, if necessary.
F1
Select LEDs:
T1
Prt1
F2
F3
If you chose T1, the LED Display screen lists the
LED signals, two at a time, on the second line. A
vertical bar at the left of the LED name indicates
the condition is ON, while an underscore indicates
the condition is Off.
F1
LED Display:
_Test
_NetSig
F2
F3
If you chose Prt1, the Port 1 LEDs screen lists the
LED signals, two at a time, on the second line. A
vertical bar at the left of the LED name indicates
the condition is ON, while an underscore indicates
the condition is Off.
F1
Port 1 LEDs:
_DTR _TXD
F2
F3
5. Use the
and
keys to scroll LED names
onto the screen.
Changing Configuration
Options
The DSU/CSU is an intelligent device that displays
only valid options for the current configuration.
Therefore, you are only presented with menu choices that
are consistent with the current configuration and
operational state of the DSU/CSU; invalid combinations
of configuration options do not appear. Be aware that
although all options are shown in this guide, what you see
on your DSU/CSU varies with your configuration.
The DSU/CSU offers configuration options located in
the following memory areas:
•
Active (Activ). This is the configuration option set
currently active for the DSU/CSU. Before a
configuration option set becomes active for the
DSU/CSU, you must save the set to the Active area.
When the DSU/CSU is shipped from the factory,
the Active configuration option set is identical to
the Factory set. This area can be written to and
controls the current operation of the device.
•
Customer 1 (Cust1). This is the first of two sets of
customer-defined configuration options. This area
can be written to.
•
Customer 2 (Cust2). This is the second of two sets
of customer-defined configuration options. This
area can be written to.
•
Factory 1 (Fact1). This is a set of configuration
options preset at the factory. This set is determined
by what is considered to be the most common
configuration used in the DSU/CSU market.
Factory 1 options are read-only.
•
Factory 2 (Fact2). This is a set of configuration
options preset at the factory. This set is determined
by what is considered to be the second most
common configuration used in the DSU/CSU
market. Factory 2 options are read-only.
Содержание 3163
Страница 1: ...ACCULINK 3163 DSU CSU USER S GUIDE Document No 3163 A2 GB20 10 March 1999...
Страница 6: ...ACCULINK 3163 DSU CSU E March 1999 3163 A2 GB20 10...
Страница 22: ...ACCULINK 3163 DSU CSU 2 8 March 1999 3163 A2 GB20 10...
Страница 52: ...ACCULINK 3163 DSU CSU 3 30 March 1999 3163 A2 GB20 10...
Страница 72: ...ACCULINK 3163 DSU CSU 4 20 March 1999 3163 A2 GB20 10...
Страница 74: ...ACCULINK 3163 DSU CSU A 2 March 1999 3163 A2 GB20 10...
Страница 140: ...ACCULINK 3163 DSU CSU G 18 March 1999 3163 A2 GB20 10...
Страница 142: ...ACCULINK 3163 DSU CSU H 2 March 1999 3163 A2 GB20 10...
Страница 150: ...ACCULINK 3163 DSU CSU Glossary 8 March 1999 3163 A2 GB20 10...