Operation
3-13
3163-A2-GB20-10
March 1999
Setting the IP Address
The IP address is the address used by the Telnet system
to access the DSU/CSU (see Appendix E,
IP Network
Addressing Scenarios
). For DSU/CSUs using PPP, the IP
address can be negotiated if the network device (e.g. a
router) supports such negotiation. The IP address is
composed of four fields with three digits per field
(xxx.xxx.xxx.xxx).
The IP address is set for the MODEM port or the COM
port, depending on which one has been chosen as the
Telnet communication link. The example below assumes
that an IP address of 010.155.111.222 is being set for the
COM port. You can use the same principles to assign any
value (between 000 and 255 for each digit field) to the
modem port.
"
Procedure
To assign an IP address to the COM port:
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the
key until the
Mgmt selection appears on the screen.
5. Select Mgmt.
F1
Edit:
User
Alarm Mgmt
F2
F3
6. From the Mgmt Config screen, select Gen.
F1
Mgmt Config:
Gen
F2
F3
7. Press F1 (Next) until the Com IP Adr
configuration option appears.
NOTE
Steps 8 and 9 describe the
process for entering an IP
address. This process applies to
any IP address.
8. Press F2 (Edit) to edit the IP address. You have the
option of using F3 (Clear) to reset the IP address
to the factory default 000.000.000.000.
F1
Com IP Adr:
Next
Edit
Clear
F2
F3
9. Use the
and
keys to position the cursor
under the digit you want to change. Press F1 (Up)
to increment the digit or F2 (Down) to decrement
the digit. In this example, you would press
once to place the cursor under the middle digit in
the first digit field, then press F1 (Up) once to
change the 0 to a 1. Continue in this manner to
change the other digits.
F1
000.000.000.000
Up
Down
Save
F2
F3
10. When you are through changing the IP address,
you must press F3 (Save) to save the value.
Otherwise, the original value will be retained.
F1
010.155.111.222
Up
Down
Save
F2
F3
Содержание 3163
Страница 1: ...ACCULINK 3163 DSU CSU USER S GUIDE Document No 3163 A2 GB20 10 March 1999...
Страница 6: ...ACCULINK 3163 DSU CSU E March 1999 3163 A2 GB20 10...
Страница 22: ...ACCULINK 3163 DSU CSU 2 8 March 1999 3163 A2 GB20 10...
Страница 52: ...ACCULINK 3163 DSU CSU 3 30 March 1999 3163 A2 GB20 10...
Страница 72: ...ACCULINK 3163 DSU CSU 4 20 March 1999 3163 A2 GB20 10...
Страница 74: ...ACCULINK 3163 DSU CSU A 2 March 1999 3163 A2 GB20 10...
Страница 140: ...ACCULINK 3163 DSU CSU G 18 March 1999 3163 A2 GB20 10...
Страница 142: ...ACCULINK 3163 DSU CSU H 2 March 1999 3163 A2 GB20 10...
Страница 150: ...ACCULINK 3163 DSU CSU Glossary 8 March 1999 3163 A2 GB20 10...