Installation
2-5
3163-A2-GB20-10
March 1999
Installing the Redundant –
48 Vdc Power
Supply
To install the DSU/CSU using a redundant – 48 Vdc
power supply, refer to Figure 2-5 and use the following
procedure.
"
Procedure
To install the redundant – 48 Vdc power supply:
1. Connect the black wire to the – 48 Vdc return
source B.
2. Connect the red wire to the – 48 Vdc return
source A.
3. Connect the green wire to a suitable ground.
4. Connect the orange wire to the – 48 Vdc input
source B.
5. Connect the blue wire to the – 48 Vdc input
source A.
6. Cut the white wire off at the outer insulation.
7. Plug the power connector into the DSU/CSU.
1
2
3
4
5
6
BLACK
RED
GREEN
WHITE
ORANGE
BLUE
– 48 VDC RETURN B
– 48 VDC RETURN A
GROUND
– 48 VDC INPUT B
– 48 VDC INPUT A
99-14300-02
X
DSU/CSU POWER
PLUG
TO CUSTOMER-SUPPLIED BATTERY
Figure 2-5. –
48 Vdc Redundant Source Power Supply Pinouts
Содержание 3163
Страница 1: ...ACCULINK 3163 DSU CSU USER S GUIDE Document No 3163 A2 GB20 10 March 1999...
Страница 6: ...ACCULINK 3163 DSU CSU E March 1999 3163 A2 GB20 10...
Страница 22: ...ACCULINK 3163 DSU CSU 2 8 March 1999 3163 A2 GB20 10...
Страница 52: ...ACCULINK 3163 DSU CSU 3 30 March 1999 3163 A2 GB20 10...
Страница 72: ...ACCULINK 3163 DSU CSU 4 20 March 1999 3163 A2 GB20 10...
Страница 74: ...ACCULINK 3163 DSU CSU A 2 March 1999 3163 A2 GB20 10...
Страница 140: ...ACCULINK 3163 DSU CSU G 18 March 1999 3163 A2 GB20 10...
Страница 142: ...ACCULINK 3163 DSU CSU H 2 March 1999 3163 A2 GB20 10...
Страница 150: ...ACCULINK 3163 DSU CSU Glossary 8 March 1999 3163 A2 GB20 10...