37
Cancelling the Tamper Supervision for Wireless Sirens
To cancel tamper supervision, access section
[695]
, and then press
ENTER
. The tamper supervision is disabled until the cover is replaced or after 30 minutes have elapsed.
Description of Sections [700] to [704]
The following section provides information on sections
[700]
to
[704]
. See table 25 for details.
For keypad programming instructions, refer to
Table 25: Description of sections [700] to [704]
Option Option Type
Description
OFF
ON
Option Option Type
Description
OFF
ON
Se
c
ti
o
n
[700]
1
Partitioning
Partitioning
Disabled
Enabled
Se
c
ti
o
n
[701]
1
Access/master code
options
Access code length*
6 digits
4 digits
2
General system options
Battery charging, 350 mA or 700 mA
(not applicable to SP4000, SP65, and
MG5075)
350 mA
700 mA
2
Lock master code
Disabled
Enabled
3
Audible trouble warning (except AC
failure)
Disabled
Enabled
3
Keypad options 1**
Confidential mode
Disabled
Enabled
4
Audible trouble warning on AC failure
Disabled
Enabled
4
To exit confidential mode
Enter code
Press a key
5
RF jamming supervision
RF jamming supervision
Disabled
Enabled
5
Confidential mode timer
2 mins.
5 secs.
6
General system options
Exit delay termination
Disabled
Enabled
6
REM2 version number
REM2 version number
V2.00
V2.01 or
higher
7
Tamper supervision on the bus module
Disabled
Enabled
7
Keypad options 1
Display entry delay on LCD keypad
Disabled
Enabled
8
Tamper Supervision***
Panel Tamper Supervision
Disabled
Enabled
8
Display exit delay on LCD keypad
Disabled
Enabled
Se
c
ti
o
n
[702]
1
Panic options
Panic 1
Disabled
Enabled
Se
c
ti
o
n
[703]
1
Keypad options 2
One-touch regular arming (also REM3)
Disabled
Enabled
2
Panic 2
Disabled
Enabled
2
One-touch stay arming (also REM3)
Disabled
Enabled
3
Panic 3
Disabled
Enabled
3
One-touch sleep arming (also REM3)
Disabled
Enabled
4
Panic 1: report only or audible alarm
Report only
Audible
4
One-touch bypass programming
Disabled
Enabled
5
Panic 2: report only or audible alarm
Report only
Audible
5
Arming/disarming options
Restrict arming on battery failure
Disabled
Enabled
6
Panic 3: report only or audible alarm
Report only
Audible
6
Restrict arming on tamper failure (zone
+ bus wireless PGM)
Disabled
Enabled
7
Future use
-
-
-
-
-
7
Restrict arming on supervision trouble;
wireless zones & PGM + bus module
Disabled
Enabled
8
Future use
-
-
-
-
-
8
Arm/disarm with VDMP3
Arm/disarm with VDMP3
Disabled
Enabled
Sec
tion
[704]
1
Arming/disarming options
Regular arming switches to force
arming
Disabled
Enabled
= Default
*All numbers from 000000 to 999999 are valid giving a total o f 1,000,000 different possible combinations.
**Automatic timed operation that will make indications inaccessible to users without a valid access code.
***For MG5075 only.
2
Stay arming switches to stay force
arming
Disabled
Enabled
3
Sleep arming switches to sleep force
arming
Disabled
Enabled
4
Bell squawk when arm/disarm with
remote
Disabled
Enabled
5
Keypad options 3
Bell squawk when arm/disarm with a
keypad
Disabled
Enabled
6
Beep on exit delay
Disabled
Enabled
7
No exit delay beeps and no bell
squawk, when stay/sleep arm
Disabled
Enabled
8
Arming/disarming options No exit delay when arm with remote
Disabled
Enabled