42
Magellan & Spectra SP • Programming Guide
Communication Programming
Use the following section to program various communication features on your MG/SP control panel. Table 34 lists features available for each MG/SP control panel.
Prioritization of signals and messages are based on a “first in, first out” scheme. Systems meet EN 50136 ATS2 or ATS3 requirements when configured as depicted.
NOTE:
For increased security, it is suggested that redundant communication methods be installed.
Dialer Options
Table 34: Communication features for MG/SP panels
Communication Feature
Control Panel
MG5000
MG5050
SP4000
SP5500
SP6000
SP65
SP7000
GPRS reporting (PCS series)
GSM reporting and SMS (PCS series)
IP reporting (IP Module)
E-mail/monitoring (IP Module)
Patented dialer
-
Supports VDMP3
Table 35: Description of dialer options for landline communication (section [800])
Option
Description
OFF
ON
Option
Description
Sec
tion
[800]
1 & 2
Telephone line monitoring
See options 1
& 2, on right
See options 1
& 2, on right
3
Switch to pulse on fifth attempt
Disabled
Enabled
1
2
4
Alternate dial
Disabled
Enabled
OFF
OFF
Disabled (default)
5
Force dial (must be enabled to comply with TBR-21)
Disabled
Enabled
OFF
ON
Trouble only
6
DTMF dialing
Disabled
Enabled
ON
OFF
When disarmed: trouble only; when
armed: audible only
7
Pulse ratio
1:2
1:1.5
ON
ON
Silent alarms become audible alarm
8
Reporting*
Dialer
activated
No dialer
= Default
* This option also applies to both landline and GSM communication (see
Landline and GSM Communication
Table 36: Description of general communication dialer options (section [801])
Option
Description
OFF
ON
Sec
tion
[801]
1
Report system disarming
Always
After alarm
2
Report zone restore
Bell cutoff
Zone closure
3 & 4
Auto-test report transmission
5
Contact ID override
Disabled
CID defaults/slow format
custom
6
Bell squawk upon alarm report confirmation (SP4000 and SP65 only)
Disabled
Enabled
7
Bell squawk upon arming report confirmation (SP4000 and SP65 only)
Disabled
Enabled
8
Keypad beeps upon arming report confirmation (SP4000 and SP65 only)
Disabled
Enabled
= Default
Table 37: Auto-test report transmission options (section [801])
Option
Description
3
4
1
OFF
OFF
Transmit the test report code when the days programmed in section
[840]
have elapsed, at the time programmed in section
[850]
(default).
2
OFF
ON
When disarmed: transmit test report code when the time programmed in section
[852]
has elapsed. When armed: transmit test
report code when the time programmed in section
[851]
has elapsed.
3
ON
OFF
The control panel will transmit the test report code every hour, on the minute value programmed in section
[850]
(the last two
digits); the first two digits of section
[850]
will be ignored. For example, if
10:25
was programmed into section
[850]
, the test
report code would be transmitted at the 25th minute of every hour, i.e., 11:25, 12:25, etc.
4
ON
ON
The test report code will be transmitted when the conditions in entries 2 or 3 above (option 3 = OFF and option 4 = ON; option 3
= ON and option 4 = OFF), are met.
Содержание SP6000
Страница 71: ......