Keypad Lockout
Use the following section to program keypad lockout settings for your MG/SP control panel. Use worksheet 30 to record your settings.
NOTE:
For EN 50131, the keypad lockout value must be set between three and ten attempts. The minimum delay to lock must be two minutes.
Dialer Options
Timers
Use worksheet 38 to record your settings for sections
[820]
to
[840]
.
Special notes for MG5050
The Installer Quick Menu is not available anymore for MG5050 V4.96 or higher.
Section
[820]
(Fail to comm. clear event timer) is not available anymore for MG5050 V4.9 or higher.
Worksheet 57: Keypad Lockout
Section
Data
Description
Default
[716]
___/___/___
000 to 255 minutes
Keypad lockout delay
015 minutes
[717]
___/___/___
000 to 255 attempts before locking
Keypad lockout counter
005 attempts
Table 64: Description of section [801]
Option
Description
OFF
ON
Se
ct
io
n
[801]
1
Report system disarming
Always
After alarm
2
Report zone restore on closure
Bell cutoff
Zone closure
3 & 4
Auto-test report transmission
Disabled
Enabled
5
Contact ID override
Disabled
Enabled
6
Future use
7
Future use
8
Future use
= Default
Worksheet 58: Communication Timers
Section
Data
Description
Default
[820]
___/___/___
000 to 255 hours
Fail to comm. clear event timer (does not apply to SP4000 and SP65)
000 = disabled
[830]
___/___/___
000 to 255 x 2 seconds
TLM fail delay (landline only)
016
[831]
___/___/___
000 to 032
Maximum dialing attempts monitoring station (landline and GSM only)
002
[832]
___/___/___
000 to 127 seconds
Delay between dialing attempts* (landline and GSM only)
020
[833]
___/___/___
000 to 255 seconds
Delay alarm transmission
000
[836]
___/___/___
000 to 127 seconds
Personal reporting delay*
005
[837]
___/___/___
000 to 010
Personal reporting message repetition*
003
[838]
___/___/___
000 to 255 seconds
Recent closing delay
000
[839]
___/___/___
000 to 255 minutes
Power failure report delay**
015
[840]
___/___/___
000 to 255 days
Auto test report (see
001
* Also applicable when using a VDMP3 Plug-in Voice Dialer.
**The maximum value for power failure is 60 minutes.