18
Magellan & Spectra SP • Programming Guide
Custom Zone Definitions
With MG/SP control panels you can create up to four custom zone definition templates (use worksheet 8). Custom zone definition templates (sections
[033]
to
[036])
will overwrite zone definitions 33 to 36
in
table 5 on page 16. Modifications can be made in accordance with table 9 (
Permitted zone definitions for MG/SP
Zone Timers
Use the following section to program zone timers for your MG/SP control panel. Use worksheets 9 and 10 to record your settings.
NOTE:
When both ATZ and EOL are enabled, the zone speed should not be set below 300 msec.
MG Series
SP Series
Worksheet 8: Custom Zone Definitions
Section Description
Disarm
Stay Arm
Sleep Arm
Full Arm
[033]
Zone definition template 1
_____/_____
_____/_____
_____/_____
_____/_____
[034]
Zone definition template 2
_____/_____
_____/_____
_____/_____
_____/_____
[035]
Zone definition template 3
_____/_____
_____/_____
_____/_____
_____/_____
[036]
Zone definition template 4
_____/_____
_____/_____
_____/_____
_____/_____
Worksheet 9: Zone Timers for the MG Series
Section
Zone
MG5000
MG5050/MG5075
Data
Description (default: 060)
[041]
1
(Z1)
(Z1)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 1
[042]
2
(Z2)
(Z2)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 2
[043]
3
(Z1 ATZ)
(Z3)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 3
[044]
4
(Z2 ATZ)
(Z4)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 4
[045]
5
(Z5)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 5
[046]
6
(Z1 ATZ)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 6
[047]
7
(Z2 ATZ)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 7
[048]
8
(Z3 ATZ)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 8
[049]
9
(Z4 ATZ)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 9
[050]
10
(Z5 ATZ)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 10
[051]
11
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 11
[052]
12
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 12
[053]
13
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 13
[054]
14
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 14
[055]
15
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 15
[056]
16
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 16
Worksheet 10: Zone Timers for the SP Series
Section
Zone
SP4000
SP5500
SP6000
SP65*
SP7000**
Data
Description (default: 060)
[041]
1
(Z1)
(Z1)
(Z1)
(Z1)
(Z1)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 1
[042]
2
(Z2)
(Z2)
(Z2)
(Z2)
(Z2)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 2
[043]
3
(Z3)
(Z3)
(Z3)
(Z3)
(Z3)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 3
[044]
4
(Z4)
(Z4)
(Z4)
(Z4)
(Z4)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 4
[045]
5
(Z1 ATZ)
(Z5)
(Z5)
(Z5)
(Z5)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 5
[046]
6
(Z2 ATZ)
(Z1 ATZ)
(Z6)
(Z6)
(Z6)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 6
[047]
7
(Z3 ATZ)
(Z2 ATZ)
(Z7)
(Z7)
(Z7)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 7
[048]
8
(Z4 ATZ)
(Z3 ATZ)
(Z8)
(Z8)
(Z8)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 8
[049]
9
(Z4 ATZ)
(Z1 ATZ)
(Z9)
(Z9)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 9
[050]
10
(Z5 ATZ)
(Z2 ATZ)
(Z1 ATZ)
(Z10)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 10
[051]
11
(Z3 ATZ)
(Z2 ATZ)
(Z11)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 11
[052]
12
(Z4 ATZ)
(Z3 ATZ)
(Z12)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 12
[053]
13
(Z5 ATZ)
(Z4 ATZ)
(Z13)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 13
[054]
14
(Z6 ATZ)
(Z5 ATZ)
(Z14)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 14
[055]
15
(Z7 ATZ)
(Z6 ATZ)
(Z15)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 15
[056]
16
(Z8 ATZ)
(Z7 ATZ)
(Z16)
____/____/____
(000 to 255) x 10 msec.
Speed of hardwire zone 16
* For zones 17-18 (ATZ), the zone timer is set to 600 msec.
** For zones 17-32 (ATZ), the zone timer is set to 600 msec.
Содержание SP6000