Note: These features are not recommended for regu-
lar use because leaving zones open can reduce the
efficiency of system protection. (Force arming and
auto bypass away arming are ideal for use with over-
head garage doors!)

"No movement" supervision feature
Your panel can be programmed to send a report and/or
arm the system if it is not armed (full or “Stay arming”)
and there is no zone activity for a preprogrammed
amount of time. This is a particularly useful feature
when supervising the elderly, individuals with chronic
health problems or an individual that lives alone.

Automatically Arm on Time
Your installer can program your system to arm at a
specific time each day. In this mode, all protected
zones and detection devices must be in the "normal"
state before arming can occur.

Panic zones
If you need to signal a “panic” situation, the Esprit
provides three "panic" zones on your keypad. These
panic zones must be programmed by your installer.
Pressing keys [1] and [3] simultaneously for 2 sec.
will generate a “panic 1” or, if programmed, a “panic
alarm”. Pressing keys [4] and [6] simultaneously for
2 sec. will generate a “panic 2” or, if programmed, a
“auxiliary alarm”. Pressing keys [7] and [9] simulta-
neously for 2 sec. will generate a "panic 3" or, if pro-
grammed, a "fire alarm".

Based on your needs, your installer can program
these panic zones to generate audible alarms (sirens
or bells) or silent alarms, both of which also can be
sent directly to your central security station. The 3 dif-
ferent panic zones can also communicate specific
messages to your monitoring station, i.e. pressing
“panic 1” means "call the police", pressing “panic 2”
means "call an ambulance”, pressing “panic 3”
means “call the fire department". Ask your installer
for the exact definition of your panel's panic alarms.

DISARMING THE SYSTEM 

(without partitioning)

Enter the area using the designated entry-exit
door(s). The keypad sounder emits a constant tone
to remind you to disarm your system. Enter your user
code on the keypad before the entry time expires. If
you make a mistake while entering this code, press
[

CLEAR

and re-enter it. The "

ARMED

" light will go off

and the sounder will stop. 

SYSTEM ARMING/DISARMING 

(with partitioning)

Zones can be divided into two systems. Based on
your requirements, the installer designates which
zones belong to "System A" or "System B", both sys-
tems (dual area)

À

À

, or are not given a system assign-

ment (common area). A zone belonging to a “dual
area” is armed if either “System A” or “System B” is
armed, and disarmed only when both systems are
disarmed.

À

À 

 

Control panel software versions 2.00 and beyond.

14

15

UM616-626

UM616-626

Содержание Paradox Esprit 616LED

Страница 1: ...READY ESPRIT 616 Model 626 Model 10 AWAY 6 12 9 3 0 4 7 1 11 5 8 2 BYP CLEAR ENTER STAY TRBL 2ND MEM READY ARMED P R D O X S E C U R I T Y S Y S T E M S PRINTED IN CANADA P R D O X S E C U R I T Y S Y...

Страница 2: ...ope that you ve already been impressed by its compact design and attractively styled keypads with their adjustable illu mination levels The dwelling or building that you want to secure can be divided...

Страница 3: ...rt of the last 256 events This reduces time and expense devoted to security supervision and can be performed in minutes Look Everything you need to know about your security system is clearly and simpl...

Страница 4: ...can activate User Codes 01 16 or 01 48 on control panels soft ware version 3 00 and beyond can be programmed by your installer to arm disarm the system activate STAY or AWAY arming and zone bypassing...

Страница 5: ...and the ENTER key will stay on 3 Key in 4 or 6 digits of the user code number and press ENTER The CONFIRMATION beep will be heard again The ENTER key will flash A four or six digit user code has been...

Страница 6: ...move around your home or commercial building while certain designated zones are armed You might choose to have entry exit points like doors or win dows protected or the basement or perhaps all the zon...

Страница 7: ...panel models 728 728 EXPRESS and 738 EXPRESS using software version 2 1X keys indicated will not flash but will be constantly illuminated Software versions 2 2X onward keys indicated do not illuminate...

Страница 8: ...pass information every time you arm Control panel software versions prior to 2 00 5 AUTO BYPASS Away arming AWAY CODE Control panel software versions prior to 2 00 If you want to arm the system withou...

Страница 9: ...2 sec will generate a panic 3 or if pro grammed a fire alarm Based on your needs your installer can program these panic zones to generate audible alarms sirens or bells or silent alarms both of which...

Страница 10: ...d 738 EXPRESS using software versions 2 1X onward keys indicated will not flash but will be con stantly illuminated Note System A codes can stop sirens coming from System B zones and vice versa but wi...

Страница 11: ...t the chime feature has been activated If a continuous beep is heard this means that the chime is off The keypad zone chime is enabled by pressing key 8 If you have more than one keypad in your system...

Страница 12: ...ower failure can be excluded from key TRBL display by your installer When a power supply failure trouble occurs TRBL key flashes rapidly Key 3 AC power failure Control panel software versions prior to...

Страница 13: ...oss of the telephone line Key 11 Fire trouble If the fire zone is cut the fire zone key and trouble key 11 will illuminate Most of these trouble conditions will be programmed by your installer to be r...

Страница 14: ...or the Disabled For special circumstances where life safety of some occupant s depends upon prompt rescue by others the fire warning system includes a means of prompt automatic notification to those w...

Страница 15: ...tes Press ENTER MEM Panel time Key MEM flashes Enter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes Press ENTER BYP Test report If programmed by your installer this sends a test report co...

Страница 16: ...l l l l l l l Zone 9 l l l l l l l l Zone 10 l l l l l l l l Zone 11 l l l l l l l l Zone 12 l l l l l l l l ZONE DESCRIPTION PARTITIONING l l Yes l l No SYSTEM 24 Bypass ACTIVATED A B Hr Enabled Zone...

Страница 17: ...l l l l l User 22 l l l l l l l l User 23 l l l l l l l l Name Code Arming Priority Reg Stay Away Byp A B User 24 l l l l l l l l User 25 l l l l l l l l User 26 l l l l l l l l User 27 l l l l l l l...

Страница 18: ...ed You have one exit time and up to two individual entry times i e Zone 1 Front door delay 1 30 sec Zone 7 Garage door delay 2 90 sec You have seconds to EXIT your premises Your Entry delay 1 is secon...

Страница 19: ...o code required Enabled by installer FAST STAY ARM key Press for 2 sec and system stay arms automatically No code required Enabled by installer Activates STAY arming To stay on the premises but still...

Страница 20: ...r complete warranty information In all cases the warranty does not cover malfunctions arising from installer error or failure to follow installation operation instructions nor does it apply to damages...

Отзывы: