for the "

READY

" light before “Stay“ arming, however all

zones that have been programmed by your installer
to arm in "Stay" mode, must be "closed" (no move-
ment in the zones when arming the system).

Pressing key [

STAY

/11] steadily for 2 seconds will

automatically "Stay" arm the system. 

Double “Stay” arming:

During the exit delay, pressing [

STAY

/11] again will

switch any “delay 1” or “delay 2” zones to “instant”
zones. 24 hour “Stay” zones, follow “Stay” zones,
and instant “Stay” zones are not affected. Full system
arming cancels “double stay” arming.

Fast exit:

Exit while the system is armed in “Stay” mode (key
[

STAY

/11] is flashing

*

):

A: fast exit and stay key [11]:
To exit the premises and remain “Stay” armed, press
key [

STAY

/11] for two seconds. The system will switch

to “exit delay” mode (“

READY

” LED flashes). At the

end of the “exit delay” period, the system will return
to “Stay” arming mode.

B: fast exit and regular arm key [10] arm: 
Press key [10] for two seconds. The system will switch
to “regular” arming (keys [11] and [12] flash

*

) with an

“exit delay” (“

READY

” LED flashes). At the end of the

“exit delay” period, the system is “regular” armed.

*

On control panel models 728728 EXPRESS and 738

EXPRESS using software version 2.1X, keys indicated
will not flash, but will be constantly illuminated.
Software versions 2.2X onward, keys indicated do not
illuminate. However, if system is “Stay” armed, [

STAY

]

key will illuminate.

Key switch/Push-button Arming
Your system can include a key switch or push button
that arms/disarms the system. This arming method is
particularly useful when installed in a master bed-
room, making system arming and disarming conve-
nient and accessible. The beautifully styled Esprit
PS1 bedside remote has been specifically designed
for this application and includes a panic zone.

If an alarm is generated in your system, or a zone
that has not been defined as a “Stay” zone is opened
after panel arming, the system can only be disarmed
from a keypad (if keyswitch is defined as "Stay" arm-
ing)using an access code.
Please ask your installer for more information.

(4) MANUAL BYPASS arming

[

BYP

CODE

(Arms the system while bypassing defective zones
and/or zones you wish to leave open)

Note: When you bypass a zone, it is no longer mon-
itored by the security system. It will not generate an
alarm on the control panel. 

You might not wish to arm the entire system when,
for example, workers are renovating part of your

10

11

UM616-626

UM616-626

Содержание Paradox Esprit 616LED

Страница 1: ...READY ESPRIT 616 Model 626 Model 10 AWAY 6 12 9 3 0 4 7 1 11 5 8 2 BYP CLEAR ENTER STAY TRBL 2ND MEM READY ARMED P R D O X S E C U R I T Y S Y S T E M S PRINTED IN CANADA P R D O X S E C U R I T Y S Y...

Страница 2: ...ope that you ve already been impressed by its compact design and attractively styled keypads with their adjustable illu mination levels The dwelling or building that you want to secure can be divided...

Страница 3: ...rt of the last 256 events This reduces time and expense devoted to security supervision and can be performed in minutes Look Everything you need to know about your security system is clearly and simpl...

Страница 4: ...can activate User Codes 01 16 or 01 48 on control panels soft ware version 3 00 and beyond can be programmed by your installer to arm disarm the system activate STAY or AWAY arming and zone bypassing...

Страница 5: ...and the ENTER key will stay on 3 Key in 4 or 6 digits of the user code number and press ENTER The CONFIRMATION beep will be heard again The ENTER key will flash A four or six digit user code has been...

Страница 6: ...move around your home or commercial building while certain designated zones are armed You might choose to have entry exit points like doors or win dows protected or the basement or perhaps all the zon...

Страница 7: ...panel models 728 728 EXPRESS and 738 EXPRESS using software version 2 1X keys indicated will not flash but will be constantly illuminated Software versions 2 2X onward keys indicated do not illuminate...

Страница 8: ...pass information every time you arm Control panel software versions prior to 2 00 5 AUTO BYPASS Away arming AWAY CODE Control panel software versions prior to 2 00 If you want to arm the system withou...

Страница 9: ...2 sec will generate a panic 3 or if pro grammed a fire alarm Based on your needs your installer can program these panic zones to generate audible alarms sirens or bells or silent alarms both of which...

Страница 10: ...d 738 EXPRESS using software versions 2 1X onward keys indicated will not flash but will be con stantly illuminated Note System A codes can stop sirens coming from System B zones and vice versa but wi...

Страница 11: ...t the chime feature has been activated If a continuous beep is heard this means that the chime is off The keypad zone chime is enabled by pressing key 8 If you have more than one keypad in your system...

Страница 12: ...ower failure can be excluded from key TRBL display by your installer When a power supply failure trouble occurs TRBL key flashes rapidly Key 3 AC power failure Control panel software versions prior to...

Страница 13: ...oss of the telephone line Key 11 Fire trouble If the fire zone is cut the fire zone key and trouble key 11 will illuminate Most of these trouble conditions will be programmed by your installer to be r...

Страница 14: ...or the Disabled For special circumstances where life safety of some occupant s depends upon prompt rescue by others the fire warning system includes a means of prompt automatic notification to those w...

Страница 15: ...tes Press ENTER MEM Panel time Key MEM flashes Enter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes Press ENTER BYP Test report If programmed by your installer this sends a test report co...

Страница 16: ...l l l l l l l Zone 9 l l l l l l l l Zone 10 l l l l l l l l Zone 11 l l l l l l l l Zone 12 l l l l l l l l ZONE DESCRIPTION PARTITIONING l l Yes l l No SYSTEM 24 Bypass ACTIVATED A B Hr Enabled Zone...

Страница 17: ...l l l l l User 22 l l l l l l l l User 23 l l l l l l l l Name Code Arming Priority Reg Stay Away Byp A B User 24 l l l l l l l l User 25 l l l l l l l l User 26 l l l l l l l l User 27 l l l l l l l...

Страница 18: ...ed You have one exit time and up to two individual entry times i e Zone 1 Front door delay 1 30 sec Zone 7 Garage door delay 2 90 sec You have seconds to EXIT your premises Your Entry delay 1 is secon...

Страница 19: ...o code required Enabled by installer FAST STAY ARM key Press for 2 sec and system stay arms automatically No code required Enabled by installer Activates STAY arming To stay on the premises but still...

Страница 20: ...r complete warranty information In all cases the warranty does not cover malfunctions arising from installer error or failure to follow installation operation instructions nor does it apply to damages...

Отзывы: