background image

house, or for any other reason you need to leave a
zone open. If a component of your security system is
damaged, it can also be bypassed until repairs are
made. Manual bypass arming instructs the control
panel to ignore zones that you designate “open”, so
that the rest of the system can still be armed. (Based
on your instructions, only zones that your installer
has programmed “bypass-enabled” can be bypassed
during manual bypass arming, “auto-bypass
(Away)”

À

À

arming or “Stay” arming. Please note that

the fire zone can not be bypassed.)

Press the bypass [

BYP

key, followed by your 

ACCESS

CODE

. You are now in “bypass” mode. The [

BYP

key

will be illuminated and if zones are currently
bypassed they will illuminate as well. Enter the key
numbers corresponding to the zones you wish to
"bypass". Press again on the key if you wish to undo
a zone selection.

If you have entered the correct zone bypass informa-
tion, press [

ENTER

]. The [

BYP

key light will remain “on”

indicating that zones have been bypassed. If you make
an error entering zone numbers, press [

CLEAR

].

By using the “bypass recall” feature, you can rein-
state the latest zone bypass instructions saved in
memory. Press [

BYP

while in “manual bypass arm-

ing” mode and the previous bypass status will be
reestablished. This eliminates the need to enter the
same "bypass" information every time you arm.

À

À 

 

Control panel software versions prior to 2.00.

(5) AUTO BYPASS (Away) arming

[

AWAY

CODE

Control panel software versions prior to 2.00:

If you want to arm the system without manually enter-
ing zones to be bypassed on the keypad, use “Away”
auto-bypass feature. [

AWAY

ACCESS CODE

s

hould be

keyed in. The control panel will automatically bypass
any open zones after the exit delay terminates and the
system will be armed. The “

READY

” light does not have

to be on, but all open zones must be “bypass-enabled”.
If any zones have been left open, the [

BYP

light will illu-

minate to indicate that zones have automatically been
bypassed. (The fire zone cannot be bypassed.)

FORCE (Away) arming

[

AWAY

] + 

CODE

Control panel software versions 2.00 and beyond:

To arm the system rapidly without waiting for the 

READY

light, use Force “Away” arming. [

AWAY

should be

pressed, followed by a valid access code. Once the exit
delay expires, any open zones will not be considered
“activated” by the panel. Open zones will not be protect-
ed, and will not generate an alarm or prevent arming.

These “Away” zones will be activated (and therefore,
protected) as soon as they are closed. Armed status
is indicated by the [

AWAY

key flashing

*

. (The fire

zone cannot be force armed.)

*

On control panel models 728728 EXPRESS and 738

EXPRESS using software version 2.1X, key indicated
will not flash, but will be constantly illuminated. Software
versions 2.2X onward, key indicated does not illuminate.

12

13

UM616-626

UM616-626

Содержание Paradox Esprit 616LED

Страница 1: ...READY ESPRIT 616 Model 626 Model 10 AWAY 6 12 9 3 0 4 7 1 11 5 8 2 BYP CLEAR ENTER STAY TRBL 2ND MEM READY ARMED P R D O X S E C U R I T Y S Y S T E M S PRINTED IN CANADA P R D O X S E C U R I T Y S Y...

Страница 2: ...ope that you ve already been impressed by its compact design and attractively styled keypads with their adjustable illu mination levels The dwelling or building that you want to secure can be divided...

Страница 3: ...rt of the last 256 events This reduces time and expense devoted to security supervision and can be performed in minutes Look Everything you need to know about your security system is clearly and simpl...

Страница 4: ...can activate User Codes 01 16 or 01 48 on control panels soft ware version 3 00 and beyond can be programmed by your installer to arm disarm the system activate STAY or AWAY arming and zone bypassing...

Страница 5: ...and the ENTER key will stay on 3 Key in 4 or 6 digits of the user code number and press ENTER The CONFIRMATION beep will be heard again The ENTER key will flash A four or six digit user code has been...

Страница 6: ...move around your home or commercial building while certain designated zones are armed You might choose to have entry exit points like doors or win dows protected or the basement or perhaps all the zon...

Страница 7: ...panel models 728 728 EXPRESS and 738 EXPRESS using software version 2 1X keys indicated will not flash but will be constantly illuminated Software versions 2 2X onward keys indicated do not illuminate...

Страница 8: ...pass information every time you arm Control panel software versions prior to 2 00 5 AUTO BYPASS Away arming AWAY CODE Control panel software versions prior to 2 00 If you want to arm the system withou...

Страница 9: ...2 sec will generate a panic 3 or if pro grammed a fire alarm Based on your needs your installer can program these panic zones to generate audible alarms sirens or bells or silent alarms both of which...

Страница 10: ...d 738 EXPRESS using software versions 2 1X onward keys indicated will not flash but will be con stantly illuminated Note System A codes can stop sirens coming from System B zones and vice versa but wi...

Страница 11: ...t the chime feature has been activated If a continuous beep is heard this means that the chime is off The keypad zone chime is enabled by pressing key 8 If you have more than one keypad in your system...

Страница 12: ...ower failure can be excluded from key TRBL display by your installer When a power supply failure trouble occurs TRBL key flashes rapidly Key 3 AC power failure Control panel software versions prior to...

Страница 13: ...oss of the telephone line Key 11 Fire trouble If the fire zone is cut the fire zone key and trouble key 11 will illuminate Most of these trouble conditions will be programmed by your installer to be r...

Страница 14: ...or the Disabled For special circumstances where life safety of some occupant s depends upon prompt rescue by others the fire warning system includes a means of prompt automatic notification to those w...

Страница 15: ...tes Press ENTER MEM Panel time Key MEM flashes Enter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes Press ENTER BYP Test report If programmed by your installer this sends a test report co...

Страница 16: ...l l l l l l l Zone 9 l l l l l l l l Zone 10 l l l l l l l l Zone 11 l l l l l l l l Zone 12 l l l l l l l l ZONE DESCRIPTION PARTITIONING l l Yes l l No SYSTEM 24 Bypass ACTIVATED A B Hr Enabled Zone...

Страница 17: ...l l l l l User 22 l l l l l l l l User 23 l l l l l l l l Name Code Arming Priority Reg Stay Away Byp A B User 24 l l l l l l l l User 25 l l l l l l l l User 26 l l l l l l l l User 27 l l l l l l l...

Страница 18: ...ed You have one exit time and up to two individual entry times i e Zone 1 Front door delay 1 30 sec Zone 7 Garage door delay 2 90 sec You have seconds to EXIT your premises Your Entry delay 1 is secon...

Страница 19: ...o code required Enabled by installer FAST STAY ARM key Press for 2 sec and system stay arms automatically No code required Enabled by installer Activates STAY arming To stay on the premises but still...

Страница 20: ...r complete warranty information In all cases the warranty does not cover malfunctions arising from installer error or failure to follow installation operation instructions nor does it apply to damages...

Отзывы: