64
Programming Guide
SP7000 PCB Layout
Four pin connector can
be used for quick
installation of a keypad.
Used for In-Field Firmware
upgrade through a 307USB
Direct Connect Interface. See
Connecting to WinLoad on
page 57 for details.
Paradox Memory Key
(PMC-4, PMC-5)
Refer to
AC Power
& Backup Battery
Connections on
page 56.
The "
BELL
" output will
shutdown if the current
exceeds 3A.
AUX Power
Refer to transformer requirements on page 56
for Aux. Power Output. To connect additional
wiring to auxiliary power, use the red (+) and
black (-) keypad connectors. Auxiliary power will
shut down if current exceeds 1.1A. If the
auxiliary output is overloaded and is shut down,
you must disconnect all loads from the output for
at least 10 seconds before reconnecting any
load back to the auxiliary output.
This equipment must be installed and
maintained by qualified service personnel
only.
For UL and C-UL warnings, refer to the UL
and C-UL Warnings section at the back of
the Reference & Installation Manual.
The sum of the current drawn
from the BELL and AUX must
be limited to 1.3A (40VA
transformer strongly
recommended). Exceeding
this limit will overload the
panel power supply and lead
to complete system
shutdown.
Connection for Self-Contained Bell/Siren
To provide maximum lightning
protection we strongly recommend
having separate earth connections
for the dialer and zone ground
terminals.
Max. number of keypads = 15 keypads
Max. aux. current = 700 mA
Max. distance of bus module from panel = 76m (250 feet)
Max. total run of wire = 230m (750 feet)
Disconnect telephone
line before servicing.
To metallic
enclosure
Ground
clamp
AWG#14 single
conductor solid
copper wire
Cold water
pipe
grounding
For the keypad’s zone configurations, refer to the
Installer Quick Menu.
If EOL is enabled: see
section
[706]
option
[2]
. Also refer to Keypad Zone
Connections on page 55.
Refer to Single Zone
Inputs on page 55.
PGM Trigger: This jumper allows you
to choose whether the solid state
relay PGMs are grounded (-), or give
out 12V (+).
Upper Inputs = Zones 9 to 16
Lower Inputs = Zones 1 to 8
Press and hold the RESET button for five seconds. The
STATUS LED will start flashing. Within 2 seconds of this
flashing, press the reset switch again. The panel will
reset to default and restart.
* If EOL is enabled: see
section
[706]
option
[2]
.
For the keypad’s zone
configurations, refer to
Installer Quick Menu on
page 65. Also refer to
keypad zone
connections on page 55.
*
Z1 Z2 Z3 Z4 C Z5 Z6 Z7 Z8 C
Z9 Z10 Z11 Z12 C Z13 Z14 Z15 Z16 C
EBUS and Dialer used with:
VDMP3 plug-in voice module
for voice reporting
PCS Series GSM
communicator module
May be labeled
ADM2 on some
panels
May be labeled SERIAL
on some panels
LEDs
Charge LED:
Charging and battery test LED
Status LED:
• Flash once every second = Normal
• Flashes ON 1 second and OFF 1 second = Any trouble
• Always ON = Panel is using phone line
• Fast flash 6 seconds after power up = Installer lock enabled