62
Programming Guide
SP5500 PCB Layout
Four pin connector can be used
for quick installation of a SP5500
keypad.
Used for In-Field Firmware upgrade
through a 307USB Direct Connect
Interface. See Connecting to
WinLoad on page 57 for details.
Paradox Memory Key
(PMC-4, PMC5)
Refer to
AC Power
& Backup Battery
Connections on
page 56.
The "
BELL
" output will
shutdown if the current
exceeds 3A.
AUX Power
Refer to transformer requirements on page 56 for
Aux. Power Output. To connect additional wiring to
auxiliary power, use the red (+) and black (-)
keypad connectors. Auxiliary power will shut down
if current exceeds 1.1A. If the auxiliary output is
overloaded and is shut down, you must disconnect
all loads from the output for at least 10 seconds
before reconnecting any load back to the auxiliary
output.
This equipment must be installed and
maintained by qualified service
personnel only.
For UL and C-UL warnings, refer to
the UL and C-UL Warnings section at
the back of the Reference &
Installation Manual.
The sum of the current drawn
from the BELL and AUX must be
limited to 1.3A (40VA transformer
strongly recommended).
Exceeding this limit will overload
the panel power supply and lead
to complete system shutdown.
Connection for Self-Contained Bell/Siren
To provide maximum lightning
protection we strongly recommend
having separate earth connections
for the dialer and zone ground
terminals.
Max. number of keypads = 15 keypads
Max. aux. current = 700 mA
Max. distance of bus module from panel = 76m (250 feet)
Max. total run of wire = 230m (750 feet)
Disconnect telephone
line before servicing.
To metallic
enclosure
Ground
clamp
AWG#14 single
conductor solid
copper wire
Cold water
pipe
grounding
For the keypad’s zone
configurations, refer to the
Installer Quick Menu
. If EOL is
enabled: see section
[706]
option
[2]
. Also refer to Keypad
Zone Connections on page 55.
Refer to Single Zone
Inputs on page 55.
PGM +/- trigger not
supported by the
SP5500
Press and hold the RESET button for
five seconds. The STATUS LED will
start flashing. Within 2 seconds of
this flashing, press the reset switch
again. The panel will reset to default
and restart.
Charge LED:
Charging and battery test LED
Status LED:
• Flash once every second = Normal
• Flashes ON 1 second and OFF 1 second = Any trouble
• Always ON = Panel is using phone line
• Fast flash 6 seconds after power up = Installer lock enabled
EBUS and Dialer used with:
VDMP3 plug-in voice module for voice reporting
PCS Series GSM communicator module
* If EOL is enabled: see
section
[706]
option
[2]
.
For the keypad’s zone
configurations, refer to
Installer Quick Menu on
page 65. Also refer to
keypad zone
connections on page 55.