Magellan / Spectra SP
63
SP6000 PCB Layout
Four pin connector can
be used for quick
installation of a keypad.
Used for In-Field Firmware
upgrade through a 307USB
Direct Connect Interface. See
Connecting to WinLoad on
page 57 for details.
Paradox Memory Key
(PMC-4, PMC-5)
Refer to
AC Power
& Backup Battery
Connections on
page 56.
The "
BELL
" output will
shutdown if the current
exceeds 3A.
AUX Power
Refer to transformer requirements on page 56 for
Aux. Power Output. To connect additional wiring to
auxiliary power, use the red (+) and black (-)
keypad connectors. Auxiliary power will shut down
if current exceeds 1.1A. If the auxiliary output is
overloaded and is shut down, you must disconnect
all loads from the output for at least 10 seconds
before reconnecting any load back to the auxiliary
output.
This equipment must be installed and
maintained by qualified service
personnel only.
For UL and C-UL warnings, refer to the
UL and C-UL Warnings section at the
back of the Reference & Installation
Manual.
The sum of the current drawn
from the BELL and AUX must be
limited to 1.3A (40VA transformer
strongly recommended).
Exceeding this limit will overload
the panel power supply and lead
to complete system shutdown.
Connection for Self-Contained Bell/Siren
To provide maximum lightning
protection we strongly recommend
having separate earth connections
for the dialer and zone ground
terminals.
Max. number of keypads = 15 keypads
Max. aux. current = 700 mA
Max. distance of bus module from panel = 76m (250 feet)
Max. total run of wire = 230m (750 feet)
Disconnect telephone
line before servicing.
To metallic
enclosure
Ground
clamp
AWG#14 single
conductor solid
copper wire
Cold water
pipe
grounding
For the keypad’s zone configurations, refer to the
Installer Quick Menu
. If EOL is enabled: see
section
[706]
option
[2]
. Also refer to Keypad Zone
Connections on page 55.
Refer to Single Zone
Inputs on page 55.
PGM Trigger: This
jumper allows you to
choose whether the solid
state relay PGMs are
grounded (-), or give out
12V (+).
Press and hold the
RESET button for five
seconds. The STATUS
LED will start flashing.
Within 2 seconds of this
flashing, press the reset
switch again. The panel
will reset to default and
restart.
When using an SP6000 panel in
conjunction with an RTX3, all K32
and K10V/H keypads must be
versions 2.0 or higher.
* If EOL is enabled: see
section
[706]
option
[2]
.
For the keypad’s zone
configurations, refer to
Installer Quick Menu on
page 65. Also refer to
keypad zone
connections on page 55.
*
EBUS and Dialer used with:
VDMP3 plug-in voice module for voice reporting
PCS Series GSM communicator module
LEDs
Charge LED:
Charging and battery test LED
Status LED:
• Flash once every second = Normal
• Flashes ON 1 second and OFF 1 second = Any trouble
• Always ON = Panel is using phone line
• Fast flash 6 seconds after power up = Installer lock enabled