Magellan / Spectra SP
53
Remote Control (RC) User Assignment
To assign a remote:
While in the respective section, press a button on the designated remote.
To delete a remote control:
Enter [000000] in its respective section.
To view the serial number of a remote:
Refer to section
[960]
Refer to the
Master Quick Menu
in the User Guide for user code/remote control programming.
Code Entry for Action Keys (REM3)
The six action keys (PGM1 to PGM6) and disarm keys (OFF) can be programmed to require a code entry for use.
NOTE:
The
[
ARM
]
,
[
SLP
]
and
[
STAY
]
button follow the keypad section [703] options [1], [2], and [3].
[701]
REM2 Version Number
Option
OFF
ON
[6]
REM2 version number
REM2 V2.00
REM2 V2.01 or higher
[704]
Arming/Disarming Options
Option
OFF
ON
[4]
Bell squawk when arm/disarm with remote
Disabled
Enabled
[8]
No exit delay when arm with a remote
Disabled
Enabled
Section
Section
Section
Section
[651]
RC 1 for User 1
[659]
RC 9 for User 9
[667]
RC 17 for User 17
[675]
RC 25 for User 25
[652]
RC 2 for User 2
[660]
RC 10 for User 10
[668]
RC 18 for User 18
[676]
RC 26 for User 26
[653]
RC 3 for User 3
[661]
RC 11 for User 11
[669]
RC 19 for User 19
[677]
RC 27 for User 27
[654]
RC 4 for User 4
[662]
RC 12 for User 12
[670]
RC 20 for User 20
[678]
RC 28 for User 28
[655]
RC 5 for User 5
[663]
RC 13 for User 13
[671]
RC 21 for User 21
[679]
RC 29 for User 29
[656]
RC 6 for User 6
[664]
RC 14 for User 14
[672]
RC 22 for User 22
[680]
RC 30 for User 30
[657]
RC 7 for User 7
[665]
RC 15 for User 15
[673]
RC 23 for User 23
[681]
RC 31 for User 31
[658]
RC 8 for User 8
[666]
RC 16 for User 16
[674]
RC 24 for User 24
[682]
RC 32 for User 32
Section
OFF
ON
[360] [1]
All odd-numbered REM3s
= Code entry for PGM
= One-touch PGM
[2]
All odd-numbered REM3s
= Code entry disarm
= One-touch disarm
[3]
& [4]
N/A
N/A
[5]
All even-numbered REM3s
= Code entry for PGM
= One-touch PGM
[6]
All even-numbered REM3s
= Code entry disarm
= One-touch disarm
[361] [1]
REM3 #1
= Code entry for PGM
= One-touch PGM
[2]
REM3 #1
= Code entry disarm
= One-touch disarm
[3]
&
[4]
N/A
N/A
[5]
REM3 #2
= Code entry for PGM
= One-touch PGM
[6]
REM3 #2
= Code entry disarm
= One-touch disarm
[362] [1]
REM3 #3
= Code entry for PGM
= One-touch PGM
[2]
REM3 #3
= Code entry disarm
= One-touch disarm
[3]
&
[4]
N/A
N/A
[5]
REM3 #4
= Code entry for PGM
= One-touch PGM
[6]
REM3 #4
= Code entry disarm
= One-touch disarm
[363] [1]
REM3 #5
= Code entry for PGM
= One-touch PGM
[2]
REM3 #5
= Code entry disarm
= One-touch disarm
[3]
&
[4]
N/A
N/A
[5]
REM3 #6
= Code entry for PGM
= One-touch PGM
[6]
REM3 #6
= Code entry disarm
= One-touch disarm
[364] [1]
REM3 #7
= Code entry
= One-touch PGM
[2]
REM3 #7
= Code entry disarm
= One-touch disarm
[3]
&
[4]
N/A
N/A
[5]
REM3 #8
= Code entry for PGM
= One-touch PGM
[6]
REM3 #8
= Code entry disarm
= One-touch disarm
Содержание MG5050
Страница 71: ......