29
7.1
Zone Speed
Decimal Programming
?
Address 053
Default: 600mS
The zone speed applies to all zones whether the system is armed or disarmed. The zone speed
defines how quickly the control panel will respond to an open zone. The control panel will not
display and/or respond to an open zone until the programmed zone speed elapses. All other zone
definitions and options do not come into effect until the zone speed has elapsed.
Example: The system is armed and the zone speed is set for 1.2 seconds. A zone opens
and closes in less than 1.2 seconds the control panel will not respond (i.e. no reporting,
no alarm and no display on keypad).
The zone speed can be set from 15ms to 3.8s (001 to 255 X 15ms). This feature prevents any
momentary glitches in the system from causing an alarm or unnecessary reporting.
[
ENTER
]
+
Installer Code
+
[10] [5] [3]
+
3 digit decimal value (001-255)
+
[
ENTER
]
7.2
Advanced Technology Zoning (ATZ)
Feature Select Programming
?
Address 090, key [8]
Default: ATZ Disabled
This feature is not available on the 748 EXPRESS
control panels. Enabling the ATZ feature allows
you to install two detection devices per zone input. Each detection device will have its own zone number
and each will transmit a separate alarm code that will display on the keypad. For information on how to
connect the detection devices and how the panel recognizes them, please refer to section 2.10.
Key [8] "Off": ATZ Disabled
Key [8] "On": ATZ Enabled
[
ENTER
]
+
Installer Code
+
[10] [9] [10]
+
[8]
On/Off
+
[
ENTER
]
7.3
Intellizones
Feature Select Programming
?
Addresses 092 & 094, keys [1] to [12]
If an alarm condition occurs on a zone identified as Intellizone, the control panel will trigger a timer
and will not generate an alarm until one of the following conditions occurs within a specified period
(see
Intellizone Time Delay
below):
?
An alarm condition occurs on another zone during intellizone time delay.
?
The zone that is in alarm has restored and re-occurred during intellizone time delay.
?
The zone that is in alarm remains in alarm the entire intellizone time delay.
Note: Intellizone timer will only begin after the zone speed period has elapsed (see section 7.1).
Do not use the Intellizone feature on zones programmed with any Entry Delay! An alarm may
occur when disarming the system.
7.3.1 Intellizone Time Delay
Decimal Programming
?
Address 057
Default: 48 seconds
You can set the Intellizone Time Delay between 010 and 255 seconds. Before an Intellizone can
generate an alarm, one of three conditions must occur during this time delay (see section 7.3).
[
ENTER
]
+
Installer Code
+
[10] [5] [7]
+
3-digit decimal value (010-255)
+
[
ENTER
]
Zone Definitions
Содержание Esprit 748
Страница 1: ...748P EI01...
Страница 2: ......
Страница 23: ...19 EVENT REPORTING Event Reporting...
Страница 32: ...28 Zone Definitions ZONE DEFINITIONS...
Страница 38: ...34 ARM DISARM ALARM OPTIONS Arm Disarm Alarm Options...
Страница 61: ...57...