22
6.3
Central Station Telephone Number 2
Streamline - Section 06 & 07
?
Hexa Programming - Addresses 024-031
The control panel can communicate with two central station numbers. The control panel may at
times dial the second number depending on the selected
Reporting Options
see section 6.1. If the
central station does not have a second number, you must enter the same number as the first.
There is no default telephone number and you can enter any number from 0-9 up to a maximum of
16 digits. If you would like to enter any special keys or functions refer to table 3 below. If the
telephone number contains less than 16 digits, press the [
TRBL
] key to indicate the end of the
telephone number.
[
ENTER
]
+
Installer Code
+
[7]
+
[10] [6]
+
Telephone Number
+
[
ENTER
]
OR
[
TRBL
]
if number is <16 digits
Both Central Station Telephone Numbers must be programmed in order for event reporting
to function properly!
6.4
System Account Codes
Streamline - Section 08
?
Hexa Programming - Addresses 032-035
All report codes are preceded by a 3 or 4-digit system account code to ensure correct identification
to the central station, identifying from which security system the event originated. For example, if a
zone opens, the control panel will first send the account code followed by the appropriate report
code. In a partitioned system, the control panel can send a separate account code for each system.
This will identify to the central station from which partition the report code originated. To do so,
program a different number into each account code. Where account code #1 will represent “System
A" and account code #2 will represent “System B".
If partitioning is disabled, program the same value for both account numbers.
There are no defaults and you can enter any hexa digit from 0 to F. Please note if required, system
account codes can have 3 digits. To do so, press the [2
ND
] key followed by the 3-digit account number.
[
ENTER
]
+
Installer Code
+
[7]
+
[10] [8]
+
4-digit Account Code #1
+
4-digit Account Code #2
+
[
ENTER
]
[
ENTER
]
+
Installer Code
+
[7]
+
[10] [8]
+
[2
ND
]
+
3-digit Account Code #1
+
[2
ND
]
3-digit Account
Code #2
+
[
ENTER
]
6.5
Communicator Formats
Streamline - Section 09
?
Hexa Programming - Address 038
Default: Ademco Slow for both numbers
The following option will determine which format the control panel will use to communicate with the
Central Station. You can select a different communicator format for each
Central Station Telephone
Number
. Using table 4 below, select the appropriate communication format. The first digit
represents the Communication Format for Central Station Telephone Number 1 and the second
Table 3 - Telephone number Special Instructions
Enter special instructions in the telephone numbers using these keys:
[10]
= the number "0"
[
BYP
]
= switch from pulse to tone while dialing
[11]
=
*
[
MEM
]
= pause 4 seconds
[12]
= #
[
TRBL
]
= end of telephone number
Event Reporting
Содержание Esprit 748
Страница 1: ...748P EI01...
Страница 2: ......
Страница 23: ...19 EVENT REPORTING Event Reporting...
Страница 32: ...28 Zone Definitions ZONE DEFINITIONS...
Страница 38: ...34 ARM DISARM ALARM OPTIONS Arm Disarm Alarm Options...
Страница 61: ...57...