32
For more information on arming and disarming partitions, see section 11.5. Also see
Code Priority
in section 8.12.
7.10.1 "System A"/Stay Zones
Feature Select Programming
?
Addresses 116 & 118, keys [1] to [12]
Using the "
Feature Select Programming Method
", select which zones will be assigned to
"System A" or if the system isn’t partitioned which zones will be identified as Stay Zones. For
details on "System A" zones refer to
Partitioning
above. For details on
Stay Arming
see
section 11.4.
7.10.2 "System B" Zones
Feature Select Programming
?
Address 120 & 122, keys [1] to [12]
Using the "
Feature Select Programming Method
", select which zones will be assigned to
"System B". For details on "System B" zones refer to
Partitioning
above.
7.11 Bypass Enabled Zones
Feature Select Programming
?
Addresses 124 & 126, keys [1] to [12]
Using the "Feature Select Programming Method", select which zones will be defined as Bypass
Enabled. Only zones defined as bypass enabled can be used for
Manual Zone Bypassing
(section
11.9) or during Auto Zone Shutdown (see below).
7.11.1 Auto Zone Shutdown
Feature Select Programming
?
Address 086 key [
TRBL
]
Default: Auto Zone Shutdown Disabled
The control panel will automatically bypass any "Bypass Enabled Zones" which initiate 5
consecutive alarms in the same-armed period. Therefore, the zone will no longer generate an
alarm. After the control panel has bypassed a zone, it will report an event code to the Central
Station if programmed at addresses 448-461.
This feature is also a function of the Report Zone Restore Options (see section 6.11). If this
option is set for report zone restore on bell cut-off, the zone will only be bypassed after the
bell or siren has cut-off 5 consecutive times in the same armed period. While if the option is
set for report zone on zone closure, the zone will be bypassed when the zone has opened
and closed 5 consecutive times in one armed period.
Key [
TRBL
] "Off": Auto Zone Shutdown Disabled
Key [
TRBL
] "On": Auto Zone Shutdown Enabled
[
ENTER
]
+
Installer Code
+
[10] [8] [6]
+
[
TRBL
]
On/Off
+
[
ENTER
]
7.12 EOL Zones (Enabled/Disabled)
Feature Select Programming
?
Address 088; key [
MEM
]
If the system requires the use of 1K
?
end of line resistors on zone input terminals, enable this
feature (see
Zone Connections
in sections 2.8 to 2.10).
Key [
MEM
] "Off": Input Zones use EOL Resistors
Key [
MEM
] "On": Input Zones do not use EOL Resistors
[
ENTER
]
+
Installer Code
+
[10] [8] [8]
+
[
MEM
]
On/Off
+
[
ENTER
]
Zone Definitions