39
PGM (PROGRAMMABLE OUTPUT)
We strongly suggest using of the Espload software to program the PGM.s
9.1
PGM Types
Streamline - Sections 09
?
Hexa Programming - Address 039
These control panels have two programmable outputs (PGMs). When a PGM closes, a ground is
supplied to activate any device or relay connected to it, providing up to a maximum of 50mA (UL
30mA). When a PGM opens, the circuit is opened from ground, therefore not providing any power to
devices connected to it. To program a PGM you must define the PGM state (normally open or normally
closed), the timing (regular or timed) and you must define the type of logic ("OR", "AND", "EQUAL").
To do so, use table 7 to determine which hexa digit to program into address 039, where the first hexa
digit programmed corresponds to PGM1 and the second hexa digit corresponds to PGM2.
?
Regular N.O./N.C.
A triggered PGM will switch to its opposite state (i.e. closed to open or opened to closed). The
PGM will return to its original state once the event(s) that triggered it have terminated.
?
Timed N.O./N.C.
A triggered PGM will switch to its opposite state (i.e. closed to open or opened to closed). The
PGM will remain in its opposite state for the period programmed at address 056 (see section
9.2). If the PGM is triggered again before the period has elapsed, the PGM will remain in its
opposite state and reset the timer.
?
"OR" Logic
Will trigger a PGM when at least one event occurs from a specific group of events (e.g. key [1]
and/or key [2] is pressed on the keypad).
?
"AND" Logic
The "AND" logic will trigger a PGM when all events, or more, occur from a specific group of
events (e.g. Keys [1] and [2] are pressed simultaneously. Note that pressing those two keys in
conjunction with any other key will also trigger the PGM).
?
"EQUAL" Logic
The "EQUAL" logic will trigger a PGM only when the events from a specific group of events
occur (e.g. Key [1] and [2] are pressed. Note the PGM will only trigger when pressing keys [1]
and [2] simultaneously, if any other key is pressed at the same time (e.g. [1], [2] & [3]) the PGM
will not trigger).
[
ENTER
]
+ Installer Code +
[10] [3] [9]
+ first digit (PGM1) + second digit (PGM2) +
[
ENTER
]
PGM (Programmable Output)